What are the different factors to be considered for reactor design?The different factors required for reactor design are
(i) Size of reactor
(ii) Type ofreactor
(iii) Time or duration of reaction
(iv) Temperature & Composition of reactingmaterialinthereactor
(v) Heat removal or added and
(vi) Flow pattern of fluid in the reactor and What are ideal reactors?Ideal reactors (BR, PFR, and MFR) are relatively easy to treat. In addition, one orother usually represents the best way of contacting the reactants - no matter what theoperation. For these reason, we often try to design real reactors so that their flows approachthese ideals
Compute the mean torque if the stator current is 10 A (rms), the rotor is short-circuited, and the angle between the winding axes is 45°.
the dot regulation at 49 cfr 174.450 previously stipulated that when fire occurs in a domestic rail shipment of
The column will operate with a reflux ratio of 20. The feed will be at its boiling point. Take the relative volatility as constant at 1.1.
determine the force and the power required to overcome the skin friction.the ship is travelling in sea water(density1020kg/m^3) and at a speed of 24km/hr
A 50-kW, 250-V, short-shunt compound generator has the following data: Ra = 0.06 Ω, RS = 0.04 Ω, and Rf = 125 Ω. Calculate the induced armature voltage at rated load and terminal voltage. Take 2 V as the total brush-contact drop.
Use the van der Waals, the Soave-Redlich-Kwong, and the Peng-Robinson equations to determine the molar volumes of the saturated phases of ethylene at 260 K (the saturation pressure is 30.35 bar). Compare with the tabulated values,VL = 0.0713 l/m..
Suppose you discover after the combustion has been carried out that the thermocouple is not functioning properly. Use the final pressure gauge reading of 75.3bar to estimate the adiabatic flame temperature of cyclopentane. Do not assume ideal gas ..
The tank is heated slowly in such a way that the temperature in both parts rises at the same rate. As soon as the alarm goes off, the heating stops. Which alarm goes off, that of part A or part B?
A nickel steel rod 8 cm outer diameterorginally at a temperature of 300 Troc is suddenly immersed in a liquid at 100oc for which the convective heat transfer co efficient is 100 w/m2 0k . what is the..
One compartment is evacuated, the other contains steam at 7.5 bar, 300 °C. The latches are removed and the gas expands to fill the entire volume of the cylinder. When the system reaches equilibrium, its pressure is 1 bar. Determine the final tempe..
Suppose the pressure in the reactor eventually equilibrates (levels out) at 360 kPa. What is the equilibrium percent conversion of NO? Calculate the reaction equilibrium constant at the prevailing temperature, Kp [(atm)-0.5]