Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
The settling velocity of alum floc in a sedimentation basin is approximately 0.0014 fps. Calculate the equivalent overflow rate in gpd/ft2. What is the minimum detention time in hours to settle out the alum floc in an ideal basin with a depth of 10 ft.
Which process requires more energy: completely vaporizing 1 kg of saturated liquid water at 1 atm pressure or completely vaporizing 1 kg of saturated liquid water at 8 atm pressure
Calculate the force (in Kn) a punch press must exert if it is to punch out a large washer from a strip of 5-mm thick sheet steel with an ultimate shear strength of 400 MPa.
Find the depth and the top width of a v-notch capable of discharging a maximum of .7m^3/s and such that the head shall be 75mm for a discharge of 5.6 liters per second.
create a primary function that uses a function handle with a nested function to compute the ninimum of the function 20x^2-200x+12 over the range 0
How does the engineering classification of soils differ from he engineering classification of rocks
The number of parking tickets issued in a certain city on any given weekday has a Poisson distribution with parameter = 50. What is the approximate probability that 1 between 35 and 70 tickets are given out on a particular day
design a cylindrical composite column consisting of some steel rods, and also wrapped in nano-fiber material. The column must support a compressive axial force of 500 kips. The columns length is 5 ft.
this cuts it down to a single force that you have to solve for, regardless of what type of member it is. Prove that the forces are equal and that the lines of action are along an angle theta. HINT: Use to do equations of equilibrium.
In bridge widening projects, the method of stitching is normally employed for connecting existing deck to the new deck. What are the problems associated with this method in terms of shrinkage of concrete
A reinforced concrete beam having the cross section shown is on a simple span of 28ft. It carries uniform service loads of 3.60 kips/ft live load and 2.20 kips/ft dead load. Check the adequacy of the beam with respect to the moment.
The "Shape Factor" of a cross-section of a beam is defined as the fully plastic strength divided by the force or moment causing first yield. Thus the Shape Factor for bending is Mp/My and similarly for shear, is Vp/Vy.
In a typical home electronics device such as a stereo, TV, DVD, and/or CD player, there are many signals and transformations applied to those signals before they are presented to the user.
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd