Determine the temperature of the exiting moist air stream

Assignment Help Mechanical Engineering
Reference no: EM131016936

Moist air at 95°F, 1 atm, and a relative humidity of 30% enters a steam-spray humidification device operating at steady state with a volumetric flow rate of 5700 ft3/min. Saturated water vapor at 230°F is sprayed into the moist air, which then exits the device at a relative humidity of 50%. Heat transfer between the device and its surroundings can be ignored, as can kinetic and potential energy effects. Determine

(a) the temperature of the exiting moist air stream, in °F.

(b) the rate at which steam is injected, in lb/min.

Reference no: EM131016936

Questions Cloud

Franzi and tony expected npv : There's a 50-50 chance of strong or weak lunch economy. Franzi's and Tony's Cost of Capital is 10%. What is Franzi's and Tony's expected NPV?
Determine the mass flow rate of dry air required : The heated air is then allowed to pass over the materials being dried, exiting the dryer at 150°F, 1 atm, and 30% relative humidity. If moisture is to be removed from the materials at a rate of 2700 lb/h, determine the mass flow rate of dry air re..
Why is this relevant and what is the role of leadership : Why is this relevant and what is the role of leadership?
Is every function a relation : What is the difference between an equation that is a function and one that is not - Is every function a relation? Is every relation a function?
Determine the temperature of the exiting moist air stream : Saturated water vapor at 230°F is sprayed into the moist air, which then exits the device at a relative humidity of 50%. Heat transfer between the device and its surroundings can be ignored, as can kinetic and potential energy effects. Determine t..
Construct a dot plot to represent the data : Construct a dot plot to represent the data. Use the number line provided - The table shows the number of hours worked per server.
Determine temperature of moist air leaving spray section : Moist air at 32°C and = 77% enters the system and passes through a water spray, leaving the spray section cooled and saturated with water. The moist air is then heated to 25°C and = 45% with no change in the amount of water vapor present. For ..
Net result after the stock : A trader sold a Sep 50 straddle for $8. At expiration, the stock closed at $49. What was the net result after the stock was delivered to the trader who then sold the stock for $47.50?
Determine temperature and relative humidity at duct inlet : A fan within an insulated duct delivers moist air at the duct exit at 22°C, 60% relative humidity, and a volumetric flow rate of 0.5 m3/s. At steady state, the power input to the fan is 1.3 kW. Using the psychrometric chart, determine the tempera..

Reviews

Write a Review

Mechanical Engineering Questions & Answers

  Volume occupied by the steel

Assume that crude oil from a supertanker has density 750 kg/m'. The tanker runs aground on a sandbar. To reflect the tanker, its oil cargo is pumped out into steel barrels, each of which has a mass of 15.0 kg when empty and holds 0.120 m' of oil Y..

  Getting heat from a hot source that is 100 kpa steam going

getting heat from a hot source that is 100 kpa steam going from saturated vapor to a saturated liquid 1mw of power is

  If the robots lifting arm has an efficiency of 30 and

a robotic rover on mars finds a spherical rock with a diameter of 10 centimeters. the rover picks up the rock and lifts

  If the actual flow rate consumed by the motor is 0005 m3s

a hydraulic motor has a displacement of 130 cm3 and operates with a pressure of 105 bars and a speed of 2000 rpm. if

  Compressed adiabatically in a cylinder

A mixture is composed of 2 mol of CO2 and 4 mol of N2 is compressed adiabatically in a cylinder, from 100 kPa and 20C to 2MPa.

  A single-stage passive low-pass rc filter is designed to

a single-stage passive low-pass rc filter is designed to have acut-off frequenccy fc of 100 hz. its resistance equals

  Saturated water vapor at 200 kpa is in a constant pressure

saturated water vapor at 200 kpa is in a constant pressure piston cylinder. at this state the piston is 0.1 m from the

  A 4m long quarter-circular gate of radius 3 m and of

a 4m long quarter-circular gate of radius 3 m and of negligible weight is hinged aboutnbspits upper edge a. the gate

  A room is heated as a result of solar radiation coming in

a room is heated by an iron that is left plugged in. is this a heat or work interaction? take the entire room including

  What is the work done on the bullet how does this change if

a 9 mm xian short-barreled experimental pistol is fired and the explosive gases push the friction-free bullet out of

  Calculate average velocity of the water

Calculate average velocity of the water leaving the disks. Also, calculate the average velocity of the water between the disks at a position where the radius of the disks is 10 cm.

  A water pump increases water pressure from 10 psia to 50

a water pump increases water pressure from 10 psia to 50 psi. determine the power input required in hp to pump 1.2 ft3s

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd