Determine temperature and relative humidity at duct inlet

Assignment Help Mechanical Engineering
Reference no: EM131016932

A fan within an insulated duct delivers moist air at the duct exit at 22°C, 60% relative humidity, and a volumetric flow rate of 0.5 m3/s. At steady state, the power input to the fan is 1.3 kW. Using the psychrometric chart, determine the temperature and relative humidity at the duct inlet.

Reference no: EM131016932

Questions Cloud

Determine the temperature of the exiting moist air stream : Saturated water vapor at 230°F is sprayed into the moist air, which then exits the device at a relative humidity of 50%. Heat transfer between the device and its surroundings can be ignored, as can kinetic and potential energy effects. Determine t..
Construct a dot plot to represent the data : Construct a dot plot to represent the data. Use the number line provided - The table shows the number of hours worked per server.
Determine temperature of moist air leaving spray section : Moist air at 32°C and = 77% enters the system and passes through a water spray, leaving the spray section cooled and saturated with water. The moist air is then heated to 25°C and = 45% with no change in the amount of water vapor present. For ..
Net result after the stock : A trader sold a Sep 50 straddle for $8. At expiration, the stock closed at $49. What was the net result after the stock was delivered to the trader who then sold the stock for $47.50?
Determine temperature and relative humidity at duct inlet : A fan within an insulated duct delivers moist air at the duct exit at 22°C, 60% relative humidity, and a volumetric flow rate of 0.5 m3/s. At steady state, the power input to the fan is 1.3 kW. Using the psychrometric chart, determine the tempera..
What other industry can use this strategy : This is an opportunity for you to explore the practical application of quality research in healthcare. I encourage you to respond in first person, share personal experiences, and ask questions to further develop your understanding of quality in he..
Determine pressure of mixture at onset of condensation : A fixed amount of moist air initially at 1 bar and a relative humidity of 60% is compressed isothermally until condensation of water begins. Determine the pressure of the mixture at the onset of condensation, in bar. Repeat if the initial relative..
Puts and calls on procter and gamble : You are a trader who trades both puts and calls on Procter and Gamble. Information about current market conditions is displayed below.
Explain why beads of moisture form on the can outer surface : A can of soft drink at a temperature of 40°F is taken from a refrigerator into a room where the temperature is 70°F and the relative humidity is 70%. Explain why beads of moisture form on the can's outer surface. Provide supporting calculations.

Reviews

Write a Review

Mechanical Engineering Questions & Answers

  An octave is defined as a doubling of the frequency

An octave is defined as a doubling of the frequency. The claim is made that a low-pass Butterworth filter of order n has a roll-off (attenuation) of 6n dB/octave. Calculate the gain in dB for a second-order filter for the cut-off frequency itself, an..

  Incremental rate of return analysis

A company is trying to decide which machine to purchase based on the following information. If they all have 15 years useful life and MARR is 10%, use incremental rate of return analysis in Excel to decide which one is the best choice. Don't forge..

  Combine the uniform flow and horizontal velocity

Combine the uniform flow, horizontal velocity, U, and Doublet of Strength, M. Find and simplify the Stream function and potential function.

  Insulated piston-cylinder arrangement contains water

An insulated Piston-Cylinder arrangement contains water. Sixty percent of the total 15 kg of water are in the vapor phase. Steam at 1 Mpa and 400 C degree is allowed to enter the cylinder from a supply line until all of the liquid in the cylinder is ..

  Electrical work is employed to heat

Electrical work is employed to heat 2kg of water from 298.15 K to 373.15 K. Determine the electrical work required, and the minimum work required (e.g., by using a heat pump instead).

  For each plot use a range x or y okm to 1 km find the

the flow field for and atmospheric flow is given byv -my2pi imx2pi jwhere m1 s -1 and the x and y coordinates are the

  Effects of e and tau on the lift of van de vooren airfoil

Derive an expression for lift co-efficient of a Van de Vooren Airfoil having chord length =2l,thickness parameter E and trailing angle tau. Discuss the effects of E and tau on the lift of Van De Vooren Airfoil.

  The plant manager decided to build a model however test

axial flow coolant pump for one lop pressurized nuclear reactor has 75 m head 6m3s flow rate 1440rpm 800 mm diameter

  Oil enters a counterflow heat exchanger at 450k with a mass

oil enters a counterflow heat exchanger at 450k with a mass flow rate of 10 kgs and exits at 350k. a seperate stream of

  The exit diameter of the pipe is 0113 m find the flow rate

two streams discharge into a pipe as shown. the flows are incompressible. the volume flow rate of stream a into the

  Determining the approximate water temperature

Water flows at a velocity uoo = 1 m/s over a flat plate of length L = 0.6 m. Consider two cases, one for which the water temperature is approximately 300 K and the other for an approximate water temperature of 350 K. In the laminar and turbulent r..

  Determine the amount of money this facility will save a

during a plant visit it was noticed that a 12-m-long section of a 12-cm-diameter steam pipe is completely exposed to

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd