Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
A three-phase, wye-connected, cylindrical-rotor, synchronous motor, with negligible armature resistance and a synchronous reactance of 1.27 Ω per phase, is connected in parallel with a three phase, wye-connected load taking 50 A at 0.707 lagging power factor from a three-phase, 220-V, 60-Hz source. If the power developed by the motor is 33 kW at a power angle of 30°, determine:
(a) The overall power factor of the motor and the load.
(b) The reactive power of the motor.
A factory is producing tablets. It is required to design a system such that: The bottles moves till it reach the position shown (A) and 50 tablets are dropped in
how much is the net income, after taxes
Compute the sending-end voltage, current, real power, and reactive power for the following conditions:
Prepare a piping diagram and calculate the pipe size as well as the required power of the pump. You need to specify the type of fittings and the pipe material for your calculations.
Find the corresponding diffusion current.
Develop a two-dimensional addressing system using a 6-to-64 decoder, a 64-word×128- bit matrix, and 16-input multiplexers. How many gates would such a system require?
Determine the minimum number of stages required, and determine the minimum reflux ratio
A helicopter is in a steady vertical climb when it suddenly experiences a strong horizontal gust. Consider the conditions on the advancing and retreating sides of the disc and draw relevant blade element velocity
Determine which of the following 3 material substrates would have the best R-value or lowest thermal conductivity. The purpose is to determine which of the 3 materials would make the best insulator to heat and cold?
Draw the cycles on P-h and T-s diagrams
(Note that the number of parallel paths is equal to the number of poles for lap windings.)
How long must the tube be made if the outlet oil temperature is 60 C? The Nusselt number for oil side is 5.56. F. water side.
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd