A compressor is employed to compress gas flowing steadily through it. The gas enters the compressor at a temperature of 16°C, a pressure of 100 kPa, and with an enthalpy of 391.2 kJ/kg. The gas leaves the compressor at a temperature of 245°C, a pressure of 0.6 MPa, and with an enthalpy of 534.5 kJ/kg. There is no heat transfer to or from the gas as it flows through the compressor. Note that power has to be provided to the compressor to compress the gas.
1) Evaluate the work done per unit mass of gas assuming the gas velocities at entry and exit is negligible.
2) Evaluate the work done per unit mass of gas when the gas velocity at entry is 80 m/s and that at exit is 160 m/s.
assume that you are responsible for the design of a wide-plate tension member built from a structural aluminum. the
a flat plate separates two supersonic air flows. the flow along the upper surface has a mach number of 1.4 and a
At the proportional limit, a 1.5-in. gage length of a 0.375-in.-diameter alloy rod has elongated 0.0081 in. and the diameter has been reduced 0.00071 in. The total tension force on the rod was 5.62 kips.
a strain rosette with measurements in the direction of the applied unidirectional force perpendicular and at 45 degrees
a beam of light is emitted in a pool of water from a depth of 69.7 cm. where must it strike the air water interface
a car is climbing the hill of slope theta1 at a constant speed v. if the slope decreases abruptly to theta2 at point a
assume that a seismically excited system is accurately modeled by a mass attached to the ground by a spring and a
a mass of 12kg of refrigerant-134a initially exists as a saturated vapor in a piston-cylinder device at 240 kpa. then
assume that the heat treatment supervisor in charge of processing the some gears is on an economy program directed
Electricity might be used to run the fan to draw air through the system, and also to run a chiller - What is a typical COP for a commercial chiller?
air flowing at 4x10-4kgs and 27 degrees c enters a sqaure duct that is 200mm on the side and 2m long. the duct surface
u.s. energy use was approximately 100 quads quadrillion btu in 2008. about 85 of this energy was supplied by burning
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd