Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
A rigid adiabatic container in a room with a barometric pressure of 100 kPa is divided into two unequal volumes as shown. V1 = 0.108 m3 and contains air (R = 0.2870 kJ/kg-K, k = 1.40) at a gauge pressure of 32 kPa and temperature of -3°C. V2 = 0.264 m3 and contains helium (R = 2.0769 kJ/kg-K, k = 1.667) at a vacuum pressure of 40 kPa and a temperature of 23°C. The membrane separating the two volumes bursts and the two gases mix together. When equilibrium is restored,
1- What is the gauge pressure in the container?
2- What is the final temperature? In C
water is the working fluid in a regenerative rankine cycle with one closed feedwater heater and one open feedwater
a disk has a mass of 4kg and a radius of 90mm it is at rest when it is placed in contact with the belt which moves with
a cylindrical casting is 0.4 m in diameter and 0.6 m in length. another casting of the same metal is rectangular in
the centerboard of a sailboat is 2.5m long and has a chord of 1m. approximate the centerboard as a flat plate in water
1 a vapor power plant operates with water as the working fluid passing through the cycle at a flow rate of 12 kgs. in
a compressed air cylinder initially contains air at 25ordmc and 100 kpa. the volume of the cylinder is 0.01021 m3. the
a closed rigid stationary and adiabatic pressure vessel initially contains two-phase h2o at a pressure of 175 kpa and a
high density polyethylene may be chlorinated by inducing the random substitution of chlorine atoms for hydrogen.a
a piston cylinder device with a set of stops on the top initially contains 3 kg of air at 200kpa and 27 degrees
a rigid tank contains 5 kg of refrigerant-134a initially at 20degc and 140 kpa. the refrigerant is now cooled while
a large vessel had experienced an internal leak of a coolant. it was friday and the work crew needed to get the vessel
refrigerant 134a at -10degc 1.4 bar and a mass flow rate of 280 kghr enters an insulated compressor operating at steady
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd