Use the civil engineering method(tension concrete not used) to determine the maximum moment capacity in the beam.
What fails or yields first? Do a quick "back of the envelope" calculation to estimate the shear capacity of the beam.
What governs the capacity of the beam?
Suppose the average concentration of SO2 (SOsub2) is measured to be 400microgram/cu.m at 25degree celcius and 1 atm. Does this exceed the (24-hr) air quality standard of 0.14 ppm
The salt water mixes thoroughly with the fresh water and the mixture overflows out of the tank. If the flow rate out of the tank is 60 liters/minute. Assume freshwater is 1000 kg/m^3, and the salty water is 1020 kg/m^3.
i want to know how to draw bending moment diagram for this shape and the value of the moment in critical sections
A package is at rest on a conveyor belt which is initially at rest The belt is started and moves to the right for 1.3s with a constant 'a' and comes to a stop after a total displacement of 2.2m.
Body A and body B are connected by an inextensible cord. If both bodies are released simultaneously from rest, what distance do they move in 3 sec and what is the tension in the cord. The weight of A is 50 lb and the weight of B is 10 lb.
The outer surface of the tank is cooled by air at 300 K with a heat transfer coefficient of 100 W/m2K. Determine the maximum temperature in the tank. Take the thermal conductivity of the wastes as 2.0 W/mK.
The column is constructed from high-strength concrete and four A-36 steel reinforcing rods. If it is subjected to an axial force of 37.5 kN , determine the required diameter of each rod so that one-fourth of the load is carried by the concrete
What are the merits and demerits of concrete in construction industry?
A concrete test cylinder 200 mm in diameter by 400 mm high is tested to failure. The compressive strain at failure is 0.0012. Determine the total amount the cylinder shortens before failure.
Determine the minimum size of the pad footing 2 metres wide for a steel column if a factor of safety of 2.0 is recommended (include an estimate of self weight of the footing in your calculations). The total load of the column is 447.644kN
The member is supported by a pin at A aand a cable BC. If the load at AD is 300 lb, determine the x,y,z components of reaction at the pin A and the tension in cable b c
a force is specified by the vector F=160i+80j-120k N.calculate the angles made by F with the postive x y and z axes.