Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
A counterflow, concentric tube heat exchanger is designed to heat water from 20 to 80 °C using hot oil, which is supplied to the annulus at 160 °C and discharged at 140 °C. The thin-walled inner tube has a diameter of Di = 20 mm, and the overall heat transfer coefficient is 500 W/m2K. The design condition calls for a total heat transfer rate of 3000 W.
a. What is the length of the heat exchanger?
b. After 3 years of operation, performance is degraded by fouling on the water side of the exchanger, and the water outlet temperature is only 65 °C for the same fluid flow rates and inlet temperatures. What are the corresponding values of the heat transfer rate, the outlet temperature of the oil, the overall heat transfer coefficient, and the water-side fouling fact?
consider an r-134a compressor on a refrigeration system. if the refrigerant enters as saturated vapor at 200 kpa 0.03
a 380-liter tank contains steam initially at 300 kpa and 400degc. a valve is opened and steam flows out of the tank at
a which bearing has higher starting torque rolling element bearing or journal bearing? justify your answer.b when
a 50 lb. weight is attached to the end of a 10 inch long beam e30106 psi which is 1 inch wide and 14 and inch deep and
Find the compression ratio, cutoff ratio, the thermal efficiency, the mean effective pressure, and the P -v and T-s diagrams clearly showing all corners.
consider a lifting flow over a circular cylinder with a diameter of 0.5m.the freestream velocity is 25 ms and the
a commuter train travels along a straight path from the lincoln street stop to the san francisco street stop in six
a submarine is cruising in the ocean at a depth of 320 m. salt water has a specific gravity of 1.03. determine the
coming out of a factory chimney are the following gases co2 so2 o2 n2 h2o with volume percentage to be 13.5 0.3 5.2 76
a rankine power cycle operates with an open feedwater heater. the boiler pressure is 6.0 mpa. a superheater provides a
a solid circular shaft and a tubular shaft both with the same outer radius of cco 0.600in are being considered for a
we want to achieve a concentration of 0.5wt of carbon at a depth of 0.2 mm below the surface of the slab of a metal.
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]