Reference no: EM131274254
Modelling of a Marine Diesel engine
PART A
Use the provided Matalb/Simulink mean value code to simulate the steady state and transient operation of the MAN Diesel and Turbo 6S46MC-C7 engine. The engine MCR point is 7860 kW at 129 rpm.
Task 1: Give a short description of the model characteristics. Discuss the applications where this model type can be used and present the limitations of the model.
Task 2: perform simulation runs under steady state conditions for 40%, 50%, 65%, 90% and 100% loads. Compare the main engine operating parameters with the engine manufacturer provided data, which can be found using CEAS-ERD online application. Present tables and graphs.
Task 3: Perform transient simulation runs for the following engine load changes:
100%-65%-100%, 50%-100%-40%
Provide enough simulation time in order to obtain steady state conditions in each load change.
Present plots for the variation of the engine main operating parameters and discuss the engine transient response for each case.
PART B
Use the provided Matalb/Simulink zero-dimensional code to simulate the steady state operation of one cylinder of the MAN Diesel and Turbo K98MC engine. The engine MCR point is 5,730 kW/cyl at 94 rpm. The model is calibrated at 100% load
Task 4:
Give a short description of the model characteristics and the differences from the MVEM (discussed in Part A). Discuss the applications and the limitations of the model.
Task 5:
a) Perform runs for 100% load and compare the derived engine parameters with the manufacturer's data.
b) Calibrate the model for 75% load, perform runs and compare the derived engine parameters with the manufacturer's data.
c) Perform parametric runs in the above loads by changing i) injection timing and ii) another engine setting that you will select). Present plots for the variation of the engine main operating parameters and discuss the results for each case.
Write a program to output accumulated values for each month
: Write a program to output accumulated values for each month, given a set amount saved each month, until the accumulated amount reaches a set goal amount.
|
Impact of motivation on employees performance
: Literature review related investigate the impact of motivation on employee's performance
|
Program should promptthe user to enter the value
: Write a program that calculates the average of N integers. The program should promptthe user to enter the value for N and then afterward must enter all N numbers.
|
What consequences might be expected
: Discuss the following case in terms of virtue, non-malfeasance, and honesty. Can you identify examples of each (or their opposites) in the case study as written? Where and by whom? Explain your answers. Please do not get emotionally or personally ..
|
Perform simulation runs under steady state conditions
: 21526 &NM 951 - Marine Engineering Simulation & Modelling - perform simulation runs under steady state conditions for 40%, 50%, 65%, 90% and 100% loads. Compare the main engine operating parameters with the engine manufacturer provided data, which ..
|
Describe the key issues or challenges from this case study
: Describe the key issues/challenges/crisjs from this case study. Based on the information provided in the case study, describe and document the recommended security strategy to mitigate the issues/challenges identified.
|
Why could this rewrite be considered plagiarism
: Explainwhat it means to paraphrase and why this is an important practice for all individuals participating in academic writing. What are some additional features of academic writing that should be considered as you write papers within your program?
|
Ip address of the client
: "Your IP address is:" followed by the IP address of the machine that has connected. The IP address of the client may be obtained by using the getInetAddress method in the Socket class.
|
Multilayer infrastructure architecture
: Using Visio, create a high level large enterprise data center design that follows the Cisco®multilayer infrastructure architecture. Please use the Insert/Comment or Insert/Text Box to provide a brief explanation of each component with detail.
|