1) in a swamped common-emiter BJT amplifier, as shown below, if Vcc =12 V, R1 =8.2 kohm, R2=10 kohm, Rc = 500 ohm, Re= 1 kohm, Vbe = 0.7 V, and B =100, what is the transistor`s emitter current?
2) in the circuit given below if R1 = 220 kohm, R2 = 56 kohm, Rc = 6.8 kohm, Re = 2.2 kohm, B= 180, or 50 kohm, C1 = C2 =10 u F, Ce = 100 u F, and Vcc = 20 V determine the voltage gain AV.
How would you develop a looping program in MIPS that will take a series of decimal numbers and arrange them in ascending order from smallest to largest. The sequence of nine numbers are: 5, 3, 8, 9, 2, 4, 1, 7, 6, 3, 8
Problem on complex power, An electric load operates at 240 volts. The load absorbs an average power of 8Kw at a lagging power factor of 0.8.
A 2000kW synchronous motor operates at a three - phase line-to-line voltage of 4kV. It has a synchronous reactance of 4 ohms per phase. Calculate a) The nominal full load current of the machine when the excitation voltage E0 ( line - to-line) is 4k..
And how long it will take to reach that temperature assuming no heat lost in the process and comments on your results and may research the properties of nichrom wire to determine the resistivity of the wire
Do either or both of the reasons you gave in part (a) above also apply to a point to point voice link using frequency modulation? c. Which parameter of an FM transmission determines whether it is wideband or narrow band?
Technician B says that the resistance of a copper wire decreases as its length increases. Which of the following statements is correct?
Single Phase Circuit, A resistor and a capacitor are connected in series across a 150 V a.c supply. When the frequency is 40 Hz the current is 5 A
Indicate what data type you would use for the following variables: (a) the temperature (b) the number of days in a week (c) the number of days in a year (d) the number of months in a year
how to design boost converter and inverter parameters?
calculate the short-circuit current of a three-phase delta-wye connected transformer if the short circuit occurs between phase A and the neutral at the low voltage side, and the transformer is supplied by a 13 kV line-to-line voltage.
the worker's safety harness D-ring is attached to a 12-foot shock absorbing lanyard that is securely fastened to the structure at a point 40 feet above ground level. Does this arrangement violate OSHA standards for fall protection? Explain.
The voltage across the load must remain between 4.7 and 5.0 V for all values of load current. Design a voltage-divider network to supply the load. You may assume that resistors of any value desired are available.