Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
A large manufacturing space with an average floor to ceiling height of 30 ft has a floor area of 5000 ft^2. The total infiltration rate for the space is estimated to be 1.5 air changes per hour. The inside design temperature and relative humidity are 72F and 50%. The pressure inside the conditioned space is 11.0 Psia. The building is located in Minneapolis, Minnesota. Determine the design heating load due to infiltration for this space for a 97.5% outdoor design conditions. In making your assumptions, you may take an outdoor humidity ration of 0.0001 lbH20/lbda and air specific volume under the given outdoor design conditions may be assumed as 12.2 ft^3/lbda.
Plot the spectral blackbody emissive power of the sun versus wavelength in the range of 0.01 micro m to 1000 micro m?
A car accelerates uniformly rest to 81 ft/s over a distance of 700 ft along a curve of 800ft radius .Determine the magnitude of the total acceleration at the instant that speed of 81ft is reached.
a constriction in a pipe will cause the velocity to rise and the pressure to fall at section 2 in the throat.nbspthe
A sensitive instrument with mass 113 kg is to be installed at a location where the acceleration is 15.24 cm/(s^2) at a frequency of 20 Hz. It is proposed to mount the instrument on a rubber pad with the following properties: k=2802 N/cm and damping r..
a calculate the percentage volume change for a material being transformed from fcc to bcc. remember to assume the
5-15 air at at 300degk and 1 atm. flowing over a flat plate at 30 ms how thick is boundary layer at 2.5 cm from the
a 600 mw steam power plant operates on a simple rankine cycle. steam enters the turbine at 40 mpa and 500oc and is
many commercial sinks and publicly-accessible showers have mixing valves underneath them which pre-mix the hot and cold
superheated water vapor initially at 15 bar and 440degc is cooled at constant pressure to a saturated vapor state and
With reference to basic constructional features, contrast the methods of compression employed by positive displacement and dynamic air compressors.
a desktop computer is to be cooled by a fan. the electronic components of the computer consume 60 w of power under
as given in the sketch kerosene at 90f is being drained through 100 feet of 4 inch schedule 80 pipe from a storage tank
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd