Calculating temperature, water evaporation, and heat in a power plant cooling situation.In a nuclear power plant the cooling tower system must be run on a closed cycle. That is, the air exiting the tower passes over cooling coils to return it to its initial condition prior to reentering the tower. Air at 20 degrees C and 40% relative humidity enters the tower at a rate of 1.3 x 106 kg/sec. Water enters the tower at 50C and leaves at 25C. The water flow rate is 750,000 kg/sec. Saturated air exists the tower and passes over cooling coils which returns it to 20C and 40% relative humidity. Water at 22C condenses out of the air. Determine:
A) The temperature of air leaving the towerB) Amount of water evaporating in kg/sec.C) The heat removed by the cooling coils in kW
Questions set on Entropy, Exergy, Cycles, Otto Cycle, Rankine Cycle. In a coal fired thermal power station, indicate where the exergy contained in the coal is destroyed. For each exergy destruction mechanism, explain whether there is a small..
The steam from the nozzles of a single wheel impulse turbine discharges with a velocity of 600 m/s at an angle of 20 degrees. The blade wheel rotates at 3000 rev/min and the mean blade radius is 590 mm
The Cost of Recharging a Battery, A 12-V automotive storage battery is charged with a constant current of 2 amp for 24 hr.
Apparent Density, Theoretical Density and Void Volume, A compacted body of iron powder is sintered into a 20mm-diameter, 45-mm-tall cylinder which, upon weighing
Air enters a 0.6 m diameter fan at 16 deg C, 101 kPa, and is discharged at 18 deg C, 105 kPa, with a volumetric flow rate of 0.35 m^3/s.
A heat pump with a COP (coefficient of performance) of 2.8 is used to heat an air-tight house. When running, the heat pump consumes 5 kW of power
Consider the 2.0micrometer long GaAs device where the E-field is 5kV/cm and Mn*=.067M0. Calculate the transit time of an electron through the device if the mobility is 8000 cm^2V-s.
Fluid Statics: Submerged Submarine, A submarine is at a depth of 2000 ft from the water surface. The atmospheric pressure above the water is at 14.7 psia
What is the minimum energy in the conduction band, and where can it be found in the Brillouin zone?
How can be determined the dynamic parameters of a second order system, wiht an Inertia (M), a dampening coeficient ( C ) and a Stiffness constant ( K).
Mainframe computing used to be the only way to manage enterprise data. Then personal computers changed the data management scene. How do these two computing styles differ, and how did shift to PC-based computing evolve.
Determine the analytical solution for the maximum stress of the beam shown; compare with stress results from SolidWorks.
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd