What ground distance will be measured if grid distance is 2158m and Orthometric height = 850m, Scale factor Sf = 0.9999943, Geoidal separation N = 27m, Ra = 6371km
If the aircraft flies at 9000 m standard altitude, make a plot of drag (in N) versus speed (from stall to 240 m/s) and determine the optimum emise velocity (minimum drag per unit speed).
You are to design a chlorination tank for killing microorganisms in the effluent from a wastewater treatment plant. It is necessary to remove 99% of active bacteria in a wastewater flow of 120 m 3 /hr.
Water flows through the interior of a jet ski at 40ft^3/s. The water enters the boat at 75ft/s at an angle of 30 degrees to the water surface. The exit velocity id 85ft/s in the horizontal direction. The boat is in seawater at 60 degrees F.
Determine total delay, maximum queue length, and the time that the 20th vehicle to arrive waits from its arrival to its departure.
Briefly describe the measures that should be considered for the control of corrosion of embedded steel in concrete.
determine the dimensions of an ideal circular settling tank that can remove 0.01-in diameter particles with a specific gravity of 1.01. Use a detention time of 1.5 hours, flowrate= 4ft^3/sec, the specific weight of water=62.4 lb/ft^3
A 25-mm-diameter shaft .5 m long is pulled through a cylindrical bearing. The lubricant that fills the 0.3-mm gap between the shaft and bearing is an oil having a kinematic viscosity of 8.0 × 10-4 m2/s and a specific gravity of 0.91.
A chemical mixing basin is to be designed to blend chlorine and treated wastewater. The basin flow is 700 gallons per minute and the basin dimensions are 5 feet by 5 feet by 5 feet water depth.
Maximum dry unit weight was found to be 114lb/ft^3 at a water content of 13.5% in labratory tests. Results of a field unit weight test were dry unit weight=111lb/ft^3 and a water content 11%.
Ernst & young is currently providing support to various sectors. In this regards it was felt that if this report is able to document good practices currently being adopted or planned in ceramic sector.
What would be the Horizontal and vertical component from this acting force see diagram
Given simply supported beam with an overhang. The beam is 12 inches wide by 24 inches deep, and the slab is 6 inches deep. use a roof live load of 20 psf, and a concrete density of 150 pdf. the beams are spaced 15 feet apart.