Calculate the overall heat transfer coefficient u for the

Assignment Help Mechanical Engineering
Reference no: EM13634181

A finned-tube heat exchanger has to be designed to transfer heat from the humidified hotair to cold water. It is important to note that when the humid air temperature becomes lower than the dew-point temperature,water vapor in the air will start to condense. It is required that the heat exchanger effectiveness is 90% and has as minimum (possible) volume. The design conditions for air andwater are,                           

        

AIR

  
  

WATER

  
  

Inlet Temperature

  
  

55 °C

  
  

25 °C

  
  

Mass flow rate

  
  

0.15 kg/s

  
  

0.30 kg/s

  
  

Air inlet relative humidity

  
  

95 %

  
     
  

Air outlet relative humidity

  
  

95 %

  
     

The main objective of this project is to increase your ability to solve real world engineering problems which arecharacterized to be not well defined. That is, the given data is not enough to solve the problem. Thus, one has to make many decisions and careful assumptions such that it can be solved to meet the desire needs.

Some Considerations

Please note that sizing the heat exchanger involves determining the required heat transfer area to meet the heat duty (tube diameter, length,number of tubes and fins), and the associated overall heat transfer coefficient. In this regard you may follow the following steps:

(1) Select a configuration (e.g. finned-tube HX where fins are on the air side) and calculatethe required UA product using the epsilon -NTU or LMTD methods

(2) Apply the energy balance on the hot and cold fluids and assume that the condensate(water vapor condensed from the air) is at a temperature of 40 °C.

(3) Calculate the overall heat transfer coefficient (U) for the assumed tube diameter, finshape and material. Use correlations to estimate hot-and cold-side convectioncoefficients, conduction resistance, contact resistance (if any), and fouling resistance.

(4) Determine the area from the UA product and U value and check whether the HX volumecan be reduced by assuming different dimensions.

Reference no: EM13634181

Questions Cloud

The average rate of consumption of br- is 185times10-4 over : the average rate of consumption of br- is 1.85times10-4 over the first two minutes. what is the average rate of
Every time you go to a beach for vacation you take home a : 1 every time you go to a beach for vacation you take home a little sand to keep as a souvenir. over your lifetime you
Calculate and discuss the blood and water outlet : a cross-flow heat exchanger used in a cardiopulmonary bypass procedure cools blood flowing at 5 litermin from a body
A student collected hydrogen gas in a buret overwater at : a student collected hydrogen gas in a buret overwater at 230 c. the buret could not be submergeddeep enough in a water
Calculate the overall heat transfer coefficient u for the : a finned-tube heat exchanger has to be designed to transfer heat from the humidified hotair to cold water. it is
An economist wants to estimate the mean income for teh : an economist wants to estimate the mean income for teh first year work for a college graduate who has had the profound
A zero-order reaction has a constant rate of 16010-4ms if : the rate for a certain reaction is k 6.0010-3s-1. if the initial reactant concentration was 0.450m what will the
Why is it that a solution of sodium dichromate in sulfuric : why is it that a solution of sodium dichromate in sulfuric acid is perfect to oxidize a secondary alcohol to a
Let a b and c be independent random variables uniformly : let a b and c be independent random variables uniformly distributed over 04 03 and 06 respectively. what is the

Reviews

Write a Review

Mechanical Engineering Questions & Answers

  Consider a system operating a power cycle between thermal

consider a system operating a power cycle between thermal reservoirs at temperatures th and tc where thgttc. using 1st

  Just before it lifts off a 10500 kg airplane is traveling

just before it lifts off a 10500 kg airplane is traveling at 60 fts. the total horizontal force exerted by the planes

  An actual refrigerator absorbs 500 kj of heat from a sink

an actual refrigerator absorbs 500 kj of heat from a sink at 250 k and reject 660 kj of heat to environment at 300 k.

  Calculate the circulation rate kgs to achieve 1 ton of

consider the ideal vapor compression refrigeration cycle where the refrigerant is r134a. saturated vapor enters the

  The turbine is not well insulated and thus there is a heat

superheated steam at 500 celsius and 3 mpa enters a steady state turbine with a mass flow rate of 500 kgs. the steam

  At the bottom with a height of 05 m is liquid water on top

a 2.5 m tall steel cylinder has a cross sectional area of 1.5 m2 . at the bottom with a height of 0.5 m is liquid water

  The mean solar flux at the earths surface is 200

the mean solar flux at the earths surface is 2.00 jcm-2min-1. in a nonfocusing solar collector the temperature can

  Steam having a mass of 3kg and initially at 25mpa and

steam having a mass of 3kg and initially at 2.5mpa and 350degc has 2460kj of heat removed at constant temperature until

  Determine how much force will be required to stretch them

a set of steel reinforcing rods is to be stretched axially in tension to create a tensile stress of 30ksi prior to

  An appropriate correlation for heat transfer by natural

an appropriate correlation for heat transfer by natural commotion from a honzontal pipe to the atmosphere isnu

  Find the new optimal solution

Find the new optimal solution of the LPP if the availability of the second constraint

  Calculate the pressure in the vessel at the end of nine

this is another safety-related problem. it is concerned with the leakage of a gas from a high pressure storage tank. a

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd