Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
Reconsider Problem 11.2.3. Calculate the coil inductance L and the total stored magnetic energy before and after the air gap is cut.
Problem 11.2.3permeability of 2500. The magnetic flux density in the core is 1.25 T measured at the mean diameter of the toroid.
(a) Find the current that must be supplied to the coil.
(b) Calculate the magnetic flux in the core.
(c) Now suppose a 10-mm air gap is cut across the toroid. Determine the current that must be supplied to the coil to produce the same value of magnetic flux density as in part (a). You may neglect leakage and fringing.
This is a refrigeration cycle problem using propane (use p-H chart for propane in Appendix). 5.15 This problem is a Claude liquefaction process for methane. (Use methane p-H chart in Appendix). 6.2 (a, c, f, h, i) Here you are asked to express var..
question 1suppose the system shown below. initially the gas is at 200 kpa and occupies a volume of 0.1 m3. the spring
A fixed-bed reactor is to be designed for a hydrocracking process. The reactor will treat 320,000 lb/hr of vacuum gas oil (specific gravity 0.85) in the presence hydrogen at 650 ºF, 2000 psig, 1.0 weight hourly space velocity (WHSV).
Calculate the atomic weight (in amu) of an element (X), given the following data: 24X : 24.000 amu at 0.7879 fractional abundance 26X : 26.000 amu at 0.1017 fractional abundance 25X : 25.000 amu at 0.1113 fractional abundance
Use the masses given in the following table to calculate the change in energy when 1 mol of 232Pu nuclei and 1 mol of 231Pa nuclei are each formed from their respective number of protons and neutrons.
If the container holds 1.3 kg of dry air, what are the final specific and relative humidities of the air in the container? what is the dew point?
Steam at 100°C is passed into a condenser at a rate of 500 kg/h and leaves as water at 60°C. If the condenser is supplied with cooling water which enters at 20°C and leaves at 40°C, calculate:- how much heat per hour is extracted from the steam.
Calculate the value of Kc for the reaction Ag+(aq) + Cl-(aq) → AgCl(s) if the concentrations at equilibrium are [Ag+] = 10-8M, [Cl-] = 0.01M.
The slurry effluent from the reactor (digester), consisting of solid inert material from the ore and an aqueous solution of aluminum sulfate is then fed to a three-stage, countercurrent washing unit to separate the aqueous aluminum sulfate from th..
what drum speed in r/min is necessary to make the amount of filtrate delivered in 24 h from the rotary filter exactly equal to the maximum amount of filtrate obtainable per 24 h from the plate-and-frame filter?
It is proposed to use an existing distillation column, which is fitted with a dephlegmator (reflux condenser) that has 200 vertical, 50 mm i.d. tubes, for separating benzene from a mixture of chlorobenzenes.
describe the principles of a vapour adsorption refrigeration system and compare this to a vapour recompression system.
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd