A series voltage regulator with constant-current limiting is shown in Figure 17-47. Determine the value of if the load current is to be limited to a maximum value of 250 mA. What power rating must have?
Create a bandpass filter with cutoff frequencies of 100-1k, attenuate by at least 3db at desired frequency(100-1k) and at 60Hz attenuate by 10 db. Resistor, Capacitor, Inductor, and Op-amps can be used.
How to Calculate the value of Ceramic / Non-Polarized Capacitors? and how to Find the value of Ceramic Capacitors?
what is the purpose of the compensating gauge?
genrator feeding electrical load with impeadance z=0.01=j0.1 per unit on 10mva at 0.8 powe factor lagging. ilteration tollerance .00002.comute the load bus voltage,real and ractive powers for node 2
What is understood by the ‘‘randomness'' of the load? When can the randomness of load be simulated by discrete stochastic variables?
Does a large bolt-to-joint stiffness ratio increase or decrease the possibility of fatigue failure of the bolt and why?
Derive the exact characteristic impedance for a two-section binomial matching transformer for a normalized load impedance
Find the approximate in tegral term response at 0.8 s, assuming a 0.05-s sample time and an integral gain of 2.45 min -I. The control range is 25 to 100 psi.
The resistance per 304.8 m of copper wire uses in the extension cord of AWG 14,12,10,8 and 6 are 2.58,1.62, 1.02, 0.64 and 0.41 respectively. Assume a 2% allowable voltage drop. Show all working .
What is the nearest coherent frequency to 20 kHz when 512 samples are collected at a rate of 44 kHz? How many cycles are completed in one UTP?
A single-phase load is supplied through a 35-kV feeder whose impedance is 95 + j360 ohm and a 35-kV:2400-V transformer whose equivalent impedance is 0.23 + j 1.27 ohm referred to its low-voltage side. The load is 160kW at 0.89 leading power factor..
A coil of inductance 225mH and series resistance 25 Ω is connected in parallel with a 100uF capacitor. If the network is connected across a 250V 50Hz supply, calculate the following: The supply current (magnitude and phase angle) and The current in..