Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
1. What is the most common material used for interior walls of residences?
2. What material is sometimes required by the fire code for studs?
3. What is a roof curb? What consequences can result from failing to contact the roofing company before making a roof penetration on a bonded roof?
Write a 1,000-word essay about your chosen career. In this essay, you will include information gathered through research of external sources and your personal thoughts about your chosen career. You will use the entire writing process, from establishi..
A sinusoidal voltage source is zero at t = 0.2 microseconds and is "going positive" at that point, meaning that v(t') > 0 for t' = 0.21 microseconds. Furthermore, the voltage at t = 0 is -28 milliVolts and its next zero is at t = 8.2 microseconds
The pulse generator circuit accepts a 16 Hz pulse and converts the signal to a 1 Hz pulse, that is, a clock signal once every second. This signal is then used to drive a counter that controls how the lights are illuminated.
The voltage on bus 1 is 1.0 per unit (pu) at 30 degrees; the voltage on bus 2 is 0.95 per unit at 5 degrees. The reactance connecting bus 1 to bus 2 is 0.5 per unit Ohms, and the resistance is negligible. a)How much real power (pu) is flowing from ..
A 150kVA, 2080/208V, 60Hz, Y/Y connected, three-phase, step-down transformer consists of three identical single-phase transformers. Each transformer has the following parameter values: Rl = 0.45-ohm, Xl = 2.2-ohm , R2 = 4.5m-ohm
If the skirt has a rectangular shape 3 × 9 m, the vehicle mass is 8100 kg and the ground clearance is 3 cm, determine the airflow rate needed to maintain the cushion and the power given by the compressor to the air.
Now, suppose that an initial voltage of 1V is present at the capacitor at zero time (t = 0). Will the behavior of the circuit when a step input is applied still yield an exponential rise or will the behavior be of some other type
Calculate Is and the current I for V = 700 mV for a pn junction for which Na = 1017 / cm³, Nd = 1016 / cm³, A = 200 µm², ni = 1.5 x 10^10 / cm³, Lp = 5 µm, Ln = 10 µm, Dp = 10 cm² / s, and Dn = 18 cm² / s
Description of Transformer, An 11 kV to 415 V transformer has a rating of 100 kVA. The winding resistance and leakage reactance when referred to the secondary are 0.0142 Ohm and 0.0569 Ohm respectively
Design a 2-stage voltage amplifier, the first stage a common-source and the second a source-follower. The load onthe S-F is 100 ohm, and the signal impedance is 1 K-ohm. The overall voltage gain should be -10 V/V. Use a single power supply, VDD = ..
A 3 phase, 2 winding, 230kv/115kV, delta-wye, 50MVAtransformer has a series impedance of (4.0 at angle 81 degrees) %and core losses of 1.0% at rated voltage. When the transformer issupplying a load of 40MW at a power factor of 0.80 lagging at rate..
develop a procedure for computing values of X(z) at 25 points spaced uniformly on an arc of a circle of radius 0.5, beginning at an angle of -π/6 and ending at an angle of 2π/3. The length of the sequence is 100 samples.
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd