A 13,800/480 V three-phase Wye-Delta-connected transformer bank consists of three identical 100-kVA 7967/480-V transformers. It is supplied with power directly from a large constant-voltage bus. In the short-circuit test, the recorded values on the high-voltage side for one of these transformers are
Vsc = 560 V
Isc = 12.6 A
Psc = 3300 W
If this bank delivers a rated load at 0.85 PF lagging and rated voltage, what is the line-to-line voltage on the primary of the transformer bank?
What is the voltage regulation under these conditions?
Note: In this problem, the core resistance and mutual inductance shall be ignored. The "13,800/480 V" means line-line voltage at primary is 13.8 kV and the line-line voltage and secondary is 480 V. Both are RMS values.
A state government is considering construction of a flood control dike having a life span of 15 years. History indicates that a flood occurs every 5 years, on average, and causes $600,000 in damages on each occasion.
The continuous-time sinusoid x(t) = cos(300?t) is sampled every Ts = 2.0 ms, so that x[n] = x(0.002n) For what other values of f in the range 0 Hz to 2.0 KHz does the sinusoid v(t)
A 460-V, three-phase,60-Hz system supplies power to a 10-kVA, delta-connected resistor load; a 50-kVA, 0.86 power factor induction motor, and a wye-connected synchronous motor that is operating at 0.62 power factor leading
In the plane z=5 there is a ring with a 3cm radius with its center on the z axis. The ring has a uniformly distributed charge Q. The origin 0,0,0 is at a small sphere with a mass of 0.5kg and a charge of -Q.
1) Ohm's. Law is considered one of the key foundation in electronics . Why (2) Why do we have to build and test circuits when we have simulation tools
A 50HP single phase motor operates from a 480V, 60HZ supply. When delivering full rated power the motor efficiency is 89% and the power factor is 0.78 lagging. Determine the full load current.(Hint: 746W=1HP)
A digital system has a clock generator that produces pulses at a frequency of 16 MHz. Design a circuit (draw the logic diagram) that provides a clock with a cycle time of 250 ns.
A collector modulated transmitter has a supply voltage of 48 V and an average collector current of 600 mA. What is the input power to the transmitter How much modulating signal power is needed to produce 100 percent modulation
mesh analysis involves writing and solving a number of simultaneous equations. The number of equations is equal to the number of independent loops in the circuit. Each equation is derived from the application of KVL around the loop.
Telephone signals are typically sampled at 8000 Hz. a. What is the time interval between samples b. What is the highest frequency that can be recovered from a sampled signal
Describe how an ideal inductor reacts to steady state DC and why. State the equation for finding the instanteneous current in an inductor during the transient period. Explain each part
A separately excited dc motor turns at 1200rpm when the armature is connected to a 115V source. Calculate the armature voltage required so that the motor runs at 1500rpm.