Two particles are fixed on an x axis. Particle 1 of charge 60.5 µC is located at x = -18.7 cm; particle 2 of charge Q is located at x = 9.53 cm. Particle 3 of charge magnitude 51.7 µC is released from rest on the y axis at y = 27.4 cm. What is the value of Q if the initial acceleration of particle 3 is in the positive direction of (a) the x axis and (b) the y axis?
Looking at feedback and some Opamp problems, If the unity gain frequency is 5 MHz and the midband open-loop voltage gain is 200,000, what is the cutoff frequency?
A two stage counter has two input, M and N. (a) Design a counter assuming the outputs come directly from J-K flipflops. (b) Design the counter assuming a two-stage binary counter is used with the J-K flipflops outputs decoded.
An incident -ray photon is scattered from a free electron that is initially at rest. The photon is scattered straight back at an angle of 180 degrees from its initial direction. The wavelength of the scattered photon is 9.00×10^-2 nm.
Use the simulation timing diagram to compare the worse case time to do an operation with your ALU with the worst case using the 74LS381. State which operation takes the longest and list the time required for both ALU's.
What is the maximum allowable value Xmax of X? The system is built with X-Xmax. An engineer argues that the host on the sort side of the bridge can use a minimum frame length shorter than 512 bits if they are talking to other hosts on the same sid..
X1 and X2 are two independent Gaussian random variables each with mean zero and unit variance.
Write a simple shell script called mathmagic that takes two arguments in at call time and returns to the stdout the value of the two items entered, the value of the two items added together, the value of the two items subtracted
Draw a circuit diagram to show how the CT, VT and meters are connected into the load circuit. Neglecting instrument and transformer errors, calculate the load kVA and power factor if the voltmeter, ammeter and wattmeter indicate values of 200 V, 2..
A balanced three-phase inductive load is supplied in steady state by a balanced three-phase voltage source with a phase voltage of 120Vrms. The load draws a total of 10kW at a power factor of 0.9.
A voltage divider is required to produce a 5.5 v output from a 12 v source. If one of the resistor values is 1.0 k, what value is required for the second resistor so that the voltage across the 1.0k resistor is 5.5v
Problem Feeder - Transformer, A single-phase load is supplied through a 35 kV feeder whose impedance is 115 + j380 Ohms and a 35 kV, 2400 V transformer whose equivalent impedance is 0.26 + j1.21 Ohms referred to its low voltage side.
Consider the circuit where the value of the inductor is 1H, the initial current in the inductor is iL(0)=-1A and the input source is Vs(t) = 2[u(t)-u(t-1)] and plot the corresponding current in the inductor iL(t) for all times.