A vertical run of copper tubing, 5 mm in diameter and 20 cm long, carries condensation vapor at 60?C through 27?C air. What is the total heat loss?
A small ceramic crucible (mass of 0.26 kg) has just been washed and rinsed. Before it can be reused, it must be absolutely dry. To ensure that no residual water is present, the crucible is heated to 150 C from room temperature (23 ?C). How much heat ..
the gate in the is hinged at H.the gate is 2 m wide and normal to the palne of the diagram.calculate the force required to hold the gate closed.
An ideal Rankine cycle uses water as its working fluid. The mass flow rate of water through the cycle is 150 kg/s. saturated vapour enters the turbine at 15 MPa and saturated liquid enters the pump at 10 kPa. Cooling water passes through the condense..
on an overflow structure of 50 degrees slope the water depth measured normal to the surface of the structure is 1.2 m 4
Calculate the crack length after cycles and subjected to a cyclic stress normal to the crack
a circular plate 2.5 m in diameter is submerged in an oil of specific gravity 0.8. the maximum and minimum depths of
An ideal Otto cycle has a compression ratio of 13.5, takes in air at 95kPa and 20°C and is repeated 940 times per minute. Using constant specific heats at room temperature, determine the thermal efficiency of this cycle
you are on a date. your date runs out of gas unexpectedly. you come to your own rescue by siphoning gas from another
air is expanded from 2000 kpa and 500c to 100kpa and 50c. assuming constant specific heats determine the change in
air is adiabatically compressed in a non flow process from a pressure of 14.7 psia and a temp of 70 deg to 200 psia and
Air at 14.7 psia, 50°F (DB), and 60% relative humidity is first heated to 110°F (DB) and then humidified by introducing water using an “air washer.” The air leaves the humidifying section at 70°F (DB).
What is the major assumption shear plane model theory ?