Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
1. A 3 phase, wye connected synchronous generator rated at 10kVA, 230V has a synchronous reactance of 1.2 ohms per phase and an armature resistance of 0.5 ohms per phase. Calculate the percent voltage regulation at full load if the power factor is 0.8 lagging. Draw the phasor diagram. Then, determine the power factor such that the voltage regulation is zero on full-load. 2. 150kVA 480 V, 60 Hz wye connected synchronous generator with a rated field current of 5 amps was tested and the following data was taken: The open circuit terminal voltage at rated field current was 530 volts The armature current at the short circuit condition was 300A When a DC voltage of 15 volts was applied to the two terminals, 30 amps was measured. Find the values of the armature resistance and synchronous reactance that would be used in the generator model at rated conditions. 3. A 480 volt, 60 Hz, Wye connected synchronous generator has eight poles. The synchronous reactance is 1.3 ohms. The full load armature current is 80A at 0.85 pf lagging. Friction and windage losses are 2kW and core losses are 1kW. Assume the armature resistance is negligible. The field current has been adjuested to make the terminal voltage 480V at no load. Determine the following: Speed of rotation Terminal voltage with at rated current with 0.85 pf lagging, rated current with unity power factor, and rated current with 0.85 pf leading. Draw a phasor diagram for each. What is the efficiency when operated at rated current and 0.8 pf lagging?. What is the shaft torque at full load? What is the voltage regulation at 0.8 pf lagging?
The paper includes Lithium ion battery technology with its advantages and disadvantages. The paper discusses about the Lithium air battery in which detailed reactions of Lithium with air including nonaqueous as well as aqueous are given.
Construction of different types of power transformer, significant energy savings
This document is shown a paper on Orthogonal frequency-division multiplexing with advantages, disadvantages and uses.
This assignment contains electronics engineering questions like State the commonly found components of a SCADA (Supervisory control and data acquisition) system. and decribe the function of the HMI in a SCADA system.
Prepare an Excel graph showing the individual components and summated resultant waveform of the odd harmonic series resulting in an approximate square wave.
Explain the function of the HMI in a SCADA system.
Design a 2-digit 24 second "shot-clock" countdown timer with pushbutton controller.
To understand dierent signal models To be able to model a discrete-time system and design simple signal processing algorithms.
Draw a relay construction diagram and briefly explain the operation of a relay.
Write a short technical report on Frequency Division Multiplexing
Briefly discuss the impact of electron energy, electron current and target on the Bremsstrahlung generated.
The schematic of the traffic light controller
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd