A circuit dissipates 100 W (average power) at 150 V (effective input voltage) and 2 A (effective input current). What is the power factor? Repeat if the power is 0 W; 300 W.
to understand the usage of the output ports of pic18f452 and make changes in the previous code accordingly.procedure -
An Aluminum electrolytic capacitor that has a capacitance of 75,000µ F,100WV is used in a power supply circuit. The leakage specification of this type of capacitors is 5µ A/µ F. If the voltage across this capacitor is 50 volts, what will be the le..
Determine the rate of change of flux linking a coil if 20 V are induced across a coil of 40 turns.
At this point add the following feature (modify the design and download it to the FPGA board): the yellow lights should blink (at 0.5 Hz) while the circuit is in the standby mode.
A. Make a two bit counter with The input X =0 makes the counter count from 0-3-1-0 and X=1 goes from 0-1-2-3-0. Choose two different types of flip flops to implement it. B. Describe what will happen on your circuit when the present state is 2 and ..
A 480 V permanent magnet ae motor is consuming 10 kW at power factor 0.80 lagging. Its speed is 1800 rpm. The winding resistance is 0.5 W per phase. Core losses are 100 W. Mechanical losses arc 250 W.
The motor is now connected differentially compounded. If Radj = 175 Ω, what is the no-load speed of the motor?
a) Construct a choice table for interest rates from 0% to 100%. b) Which roof should you choose if your MARR is 12% what is the actual value of the IRR on the incremental cost?
1-why placement of grounds is significant to obtaining accurate measurements when using instruments that can be grounded, such as scopes and 2) why should we never connect a DMM that is set up to measure current across a voltage supply
a sinusoidal voltage has a peak value of 15V, a frequency of 500Hz, and crosses zero with a positive slope at t=0.1 ms. write an expression for the voltage using a cosine function in terms of t and constant pi.
We have a balanced y-y system where the total power delivered to the Load is 1188 KW. wITH A lAGGING pOWER fACTOR OF 0.6. tHE LINE VOLTAGE AT THE LOAD IS 6600v. The line Impedance is 0.5+0.4j ohms.
If the switch shown is open, find the real, reactive, and apparent powers in the system. Find the total current supplied to the distribution system by the utility.