What is the maximum amount of real power transfer

Assignment Help Electrical Engineering
Reference no: EM131915982

Question 1 - A 275 kV, 450 km, 50-Hz three-phase uncompensated overhead transmission line, assumed to be loss-less, is composed of three conductors per phase with flat horizontal spacing of 10.5 m. The bundle spacing is 32 cm and conductors' diameter and GMR are 4 cm and 1.2 cm, respectively.

NOTE: Please keep at least four significant decimal points during calculation in this assignment in order to obtain more accurate results for the practical part.

(1) Determine the phase constant β, the surge impedance Zc, velocity of propagation v, and the wavelength λ of the line.

(2) Determine the ABCD parameters.

(3) Calculate voltage, current, real and reactive power at the sending end, and the percent voltage regulation of the line if the receiving end load is 900MW at 0.95 power factor lagging and at 275kV ( |VR| ≡ 275kV).

(4) What will the load be to maintain |VS| = |VR| with zero reactive power loss along the transmission line? Also calculate the load power. (Hint: Investigate the meaning of Zc in Glover and Sharma's "Power System Analysis and Design" Book).

(5) What is the maximum amount of real power that can be transferred to the load at unity power factor if the required receiving end voltage should always be no less than 0.88, per unit (|VS| ≡ 275kV)?

(6) For the original uncompensated system, if a unity power factor load of 1200MW is connected to the receiving end, the receiving end voltage will drop. Therefore, a shunt capacitor needs to be placed in the receiving end bus to support its voltage magnitude if the required receiving end voltage is 1 per unit. (|VS|≡ 275kV).

a) Calculate the value of the capacitor in Micro Farad.

b) Calculate the new ABCD matrix in this case.

c) Calculate voltage and can at the receiving end and the sending end after compensation.

(7) Series capacitive compensation of 55% of the line inductance is installed in the middle of the line.

a) What is the maximum amount of real power (unity power factor load) that can be transferred by this compensated line?

b) What are the new ABCD parameters?

c) What is the line current at this maximum loading?

d) Name two other practical methods for increasing real power transfer. (NOTE: the required receiving end voltage should always be no less than 0.88 per unit (|VS| ≡ 275kV)).

Question 2 - Write a brief report for the following questions. You MUST show your graphic results clearly in your report. An example of a Power World figure is shown as follows. Make sure you have indicated the necessary parameters. Please do not copy or forge your graphs. We will check your Power World program. If the results do not match, you will get ZERO marks. (NOTE: you do not have to do the calculation. You should use Power World to help you solve these problems.

1365_figure.png

(1) Use Power World to check your calculation in questions (4). (5), (6) and (7) in Question 1. Require 4 graphs.

(2) For the original uncompensated system in Question 1, if the load drops to one fourth of that during the day time (daytime load: 1200MW at unity power factor):

  • What is the magnitude of the receiving end voltage (assume |VS| ≡ 275kV)? Require 1 graph.
  • What can we do to maintain |VR| = 1.01 p. u.? What kind of compensation do we need? What are the parameters for the compensation? Require 1 graph.

(3) For the original uncompensated system in Question 1:

What will happen if the load is 900MW at 0.9 power factor lagging (|VS| ≡ 275 kV)? Require 1 graph.

Generally, a capacitor bank is installed at the receiving end for voltage support, in which the capacitor value is selected to improve the power factor to a value between 0.95 lagging and 0.866 leading. In this case however, receiving end voltage may fall outside of the range of 0.94 p. u. ≤ |VR| ≤ 1.04 p. u. To maintain this voltage range, what range of capacitor/inductance values are required? Require several graphs.

Question 3 - From a nuclear power plant, 10 GW are to be transmitted to a load center located 600 km away. Determine the number of three-phase, 50 Hz lines required to transmit this power for the following cases: (a) 330 kV lines with surge impedance Zc = 320 Ω; (b) 500 KV lines with Zc = 280 Ω; (c) 765 KV lines with surge impedance Zc = 270 Ω.

Assume the voltage magnitudes of both sending and receiving ends are 1 pu and the angle difference between sending and receiving voltage is 30 degree. Line mutual coupling is assumed to be negligible. All lines are also assumed to be lossless. You may need following equation about power transfer in terms of SIL

P = VSpuVRpu (SIL) (sinδ/sin(2πl/λ)) Watt

where voltages are in per unit, l is the length of the transmission line and λ is the wavelength. For the sake of simplicity, use the wavelength from Question 1 - (1) for all transmission lines. To calculate the reactance of the equivalent π circuit of a long line, you may use

X = SIL sin 2πl/λ

1) What do you think about the result? Which line configuration is more economical?

2) Intermediate stations are often built to support long transmission lines. Use your best line configuration from Question 3 - (1). Assume there are two intermediate substations that divide each line into three 200 km line sections. Based on given assumptions if one line section close to the sending end and one line section close to the receiving end are out of service, what is the amount of real power that can still be transmitted?

3) Same as Question 3 - (2). What if this time three line sections in series are out of service (one close to the generator, one in the middle and one dose to the load)? Such kind of line outage is similar to an entire long line outage without any intermediate substations. So, what do you think about the benefit of intermediate substations as compared with the situation that no intermediate substations are installed?

Question 4 - Intermediate stations are often built to support long transmission lines. Use your best line configuration from Question 3. Assume there are two intermediate substations that divide each line into three 200 km line sections. Each line segment is represented by π model with parameters R: 0, X: 0.04674, B: 0.9151 to match those for a 200 km distributed line. Use Power World to do following simulations:

1) If the load bus voltage is greater than or equal to 730 KV even with any line segment out of service, what is the maximum amount of real power that can be delivered to the load? Figures from power world showing the result are needed.

2) Same as 1). What is the maximum amount of real power transfer if any two line segments are out of service? Figures from power world showing the result are needed.

3) Same as 2). What is the maximum amount of real power transfer if any three line segments are out of service? Figures from power world showing the result are needed.

Reference no: EM131915982

Questions Cloud

What interest rates to charge a poor entrepreneur : How does this concept factor into a commercial bank manager's decision about what interest rates to charge a poor entrepreneur and a rich entrepreneur?
Define why do most cities closely regulate the cab industry : Explain the significance of treating a CPNC as a "privilege" rather than as a property right. Why do most cities closely regulate the cab industry?
The level of effectiveness in law enforcement : Identify issues within the report that relate to topics covered in this course, such as leadership, decision making, organizational culture, communication.
Why investing in kenya or bolivia might seem riskier : Microfinance has spread very quickly in low-income countries. Explain why investing in Kenya or Bolivia might seem riskier than investing in her own country.
What is the maximum amount of real power transfer : What is the maximum amount of real power transfer if any three line segments are out of service? Figures from power world showing the result are needed
Should the first amendment protect video games : Should the First Amendment protect video games from government oversight? Explain. Do we need to protect children from video games, whether violent or not?
Draw the production possibilities frontier for each country : Draw the production possibilities frontier for each country. Suppose the countries specialize. Which country will produce cars?
Analyze three of the critical infrastructure sectors : Analyze three of the critical infrastructure sectors (electrical substations, rail lines, and highway transportation) in your chosen city.
How many dozens of eggs would the family have per week : If the sisters specialized, which sister should gather the milk? If the sisters specialized, how many dozens of eggs would the family have per week?

Reviews

len1915982

3/26/2018 7:38:52 AM

NOTE: Please keep at least four significant decimal points during calculation in this assignment in order to obtain more accurate results for the practical part. Note that for all questions, you do not have to try every combination of line segment outage. Think about the symmetry of the given circuit. Criteria: Case file (.pwb) and the corresponding diagram file (.pwd) should be submitted in order to achieve a valid submission. Each case file should be named appropriately, with names identical to their corresponding diagram file. All case and diagram files should be contained in a single zip file. Make sure you have answered all the questions.

len1915982

3/26/2018 7:38:43 AM

This report (hard copy) should be no more than 12 pages (one sided only, Times New Roman font size 11, single line spacing with 2cm margin on all sides). Appendix should not be used. Surely, no tables or graphs are allowed to appear in Appendix. You should place tables and graphs into the body of the report. Submit the hard copy report through the EAIT assignment chute at the EAIT faculty office. Report should include concise summary of results for each section, along with comments and discussions. It could be as short as one sentence. Also it may be a short paragraph. Please place PowerWorld figures as close as possible to where you refer them to in the context. Solve every question showing working on document.

Write a Review

Electrical Engineering Questions & Answers

  Find the modulation index and percentage of modulation

An AM transmitter radiates 9 kW of power when the carrier is unmodulated and 10.125 kW when the carrier is sinusoidally modulated. Find the modulation index, percentage of modulation.

  Calculate the value of the led current

The diagram of FIGURE 2 shows a bi-directional opto coupler input interface circuit. When a supply voltage of 20 V is applied the LED carries a current and 2 V is dropped across it. Calculate the value of the LED current and the value of current t..

  Develop an expression for the number of white atoms

A volume is divided into two equal parts by a partition. The left volume has N atoms. The atoms have a mass m. A hole of area A is made in the partition at time t=0 A)Develop an expression for the number of white atoms on each side of the partition..

  Determine the flow rate of the recycle stream

Assuming that all of the SO3 is obtained at the exit of the separator in pure form (i.e., no oxygen or nitrogen are present), determine the flow rate of the recycle stream (per 100 mol in the feed) that is required to produce an overall conversio..

  Design an active rc circuit with the transfer function

Use a frequency analysis PSpice to plot the frequency response o the transfer function magnitude s indicated Plot at least one decade above and below an corner frequency

  Determine dominant-pole frequency and unity-gain bandwidth

Let λ = 0.02 V-1 for M10. If the transistor bias currents in M10 and Q12 are 150 μA and the current in Q13 is 300 μA, determine the dominant-pole frequency and unity-gain bandwidth.

  Create a program using asmide which utilizes the fox 11

create a program using asmide which utilizes the fox 11 68hc11 microcontroller board speech timer where max time is 5

  Levitate a conductive object in the magnetic field

Using a levitation coil, you levitate a conductive object in the magnetic field and heat within that field.

  State lenz '' s law and hence explain the term back emf

When a magnetic flux linking a coil changes, an emf is induced in the coil

  Identify the interval of interest for performing convolution

Identify the intervals of interest for performing the convolution {x[n]*h[n]} on the following LTI system. This experiment requires that you write the summations for each interval of interest, but does not required you to simplify the summations.

  Find capacitance when relative permittivity of gasoline gave

A parallel plate capacitor has gasoline as the dielectric. The area of the plate is 0.25 m^2 and the distance between two plates is 5cm. a. Find the capacitance given that the relative permittivity of gasoline is 2.

  Write function printbinary that displays the number of bits

Write a function printBinary() that displays the number of bits used VB2010. Using 'sizeof()' if the user enters and int 17 the function should display 000000000000000000000000000010001.

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd