Calculate The Average voltage generated in 6 turn full pitch coil of a 25 cycle alternator if the flux per pole is 7.2 x 10^5 maxwells. What is the effective voltage if the waveform is sinusoidal.
Design a common-emitter BJT amplifier with a gain of -100 (well above 3dB point) and a 3dB point at 100Hz. Assume beta = 100, Ic (quiescent) = 1mA, Vcc=20V. You can omit the output capacitor, but should bypass your emitter resistor.
A 12V-DC power supply that gets it's power from the 110V (RMS) wall outlet needs a transformer as a first step in generating its output. The rectification and regulation stage of the power supply needs an input voltage of 15V (peak)
One of the ways to look at programming at the assembly-language level is to consider it as putting together code fragments that do various little jobs. (This is a little higher-level than just thinking of it as a sequence of machine instructions.)
A somewhat discharged automotive battery has an open-circuit voltage of 12.5 V and supplies 50 A when a 0.1-? resistance is connected across the battery terminals.
1.)An op amp requires the design equation Vout = 5Vin & 2Vref + AgVg. What is the value of Ag 2.)The voltage dropout of a voltage regulator is 1.6 V. If a 16 V output is required, what is the minimum regulator input voltage
Problems for the basic concepts of Induction motor(IM) taking care of slip and syncronous speed and motor speed and its relationship, A 50 Hz induction motor operates in such a way that the slip is 1.45.
A tree-phase, 60Hz, 5MVA synchronous generator has balanced line-to-line voltages of 8320V at its terminals. if the generator is supplying power to delta-connected, balanced load of 5MVA at a 0.8 lagging power factor
A 50HP single phase motor operates from a 480V, 60HZ supply. When delivering full rated power the motor efficiency is 89% and the power factor is 0.78 lagging. Determine the full load current.(Hint: 746W=1HP)
If a circuit contains 3 automatic switches and we want that, with a probability of 95%, during a given time interval they are all working, what probability of failure per time interval can we admit for a single switch
1. draw a pair of concentric circles. the radius of a smaller circle has to be 40% as large as the radius of the other circle. you decide to make the radius of the smaller circle 5". what would be the circumference of the larger circle approximat..
Calculate the probability of finding an electron at the bottom edge of the conduction band. Also calculate the probability of not finding an electron at the top edge of the valance band.
A transmission line has the following per-unit-length parameters: L = 0.5 H/m, C = 200 pF/m, R = 4.0 /m, and G = 0.02 S/m. Calculate the propagation constant and characteristic impedance of this line at 800 MHz. If the line is 30 cm long