Refrigerant 134a enters a 28-cm diameter pipe steadily at 200 kPa and 200C with a velocity of 5 m/s. The refrigerant gains heat as it flows through the pipe and leaves the pipe at 180 kPa and 400C. Determine
a) the volumetric flow rate of the refrigerant at the inlet
b) the mass flow rate of the refrigerant
c) the volumetric flow rate of the refrigerant at the outlet
d) the velocity of the refrigerant at the outlet.
an 18-m long steel wire of 5mm diameter is to be used in the manufacture of a presstressed concrete beam.it is observed
one mole of an ideal gas at t 25 degc is held in a cylinder by a piston at a pressure of 1 x 107 pa. the piston
a cylinder is fitted with a frictionless piston contains 10 lbm of r-134a at 100 psia 300 f. the system is cooled at
the only information you have about a proposed site for a wind farm is that the wind blows at speeds above 25 ms 90 hrs
a well-insulated control volume operates at a steady state and has one inlet location 1 and two outlets locations 2 and
the small two-story office building shown in fig.p4.10 has 36000 ft3 of occupied space. due to cracksaound windows and
methane escapes through a small 10-7 m2 hole in a 10-m3 tank. the methane escapes so slowly that the temperature in the
you are considering two pipes to connect liquid leaving a pump to the entrance to a reactor. for a given mass flowrate
Freshwater is impounded to a height of 11 ft behind a dam as shown. Determine the magnitude and location of the resiltant force on the 4-ft by 4-ft gate.
how do i calculate the rate of change of heat with the cylinder, and the vertical temperature distribution along the cylinder's wall.
the hot and cold inlet temperatures to a concentric tube heat exchanger are thi 200degc tci 100degc respectively.
A cylinder fitted with a piston contains air at 1 Mpa pressure and 300 C temperature, at which point the volume is 0.2^3. The total external force acting on the piston is proportional to V^3. The system is now allowed to cool to room temperature of 2..