The system on site is a pressure sand filter, with a service curve. The filter is backwashed using the feed pump, at a higher flow rate, shown as backwash curve.
Service duty point : 3 m3/h
Backwash duty point : 9 m3/h
Part (a) What is the speed of the pump to achieve the service and backwash flow rates ?
Part (b) What would be the best way to control the speed of the pump ? Why ?
Part (C) The pump is set up as a fixed speed constant pressure system (pump runs once system pressure reaches 550 kPa, turns off, when pressure drops to 450 kPa plant re-starts) to maintain a system pressure of 500 kPa at the discharge of the pump. What would be the service and backwash rates from the pump
a closed gas turbine unit uses neon as the working fluid. there are two stages of compression with intercooling from
the beam is to be hoisted using two chains if the resultant force is to be 600n directed along the positive y axis
the masses of the bar and the disk are 5 kg and 10 kg respectively. the coefficient of kinetic frictionnbspbetween the
A similar measurement is made applying the force parallel to one of the cube axes. Explain why the two measurements give different values of the elastic modulus.
A pump station has been designed to lift water out of a 6 metre deep pit (vented to atmosphere) via a centrifigual pump mounted at ground level. Calculate the Net Positive Suction Head (NPSH) for the system ?
determine the electrical power input to the pump. the density of water is 1kg/l.
a ball is shot vertically into the air 50 m/s 108m from the ground. 6 seconds later, another ball is shot vertically into the air 20 m/s 58m from the ground. Find the distance where they meet in the air from the ground.
a construction crew lifts approximately 560 lb of material several times during a day from a flatbed truck to a 32 ft
during this process heat is exchanged with surrounding such that the entire air remains at 30 degree celsius at all times.determine the heat transfer for this process.
Refrigerant R-134a is compressed steadily and adiabatically in a reversible compressor. The volume flow rate entering the compressor is 800 ft3/min.
How would you calculate the sensible heat, the latent heat, and determine the latent heat of vaporization of the water vapor in this air stream as the air is cooled from 170 F to 48 F?
find the total heat loss per m length of the steam line. Find also the temperature at the interface of steam and insulation.