The block diagram for an elevator controller for a

Assignment Help Electrical Engineering
Reference no: EM13345859

The block diagram for an elevator controller for a two-floor elevator follows. The inputs FB1 and FB2 are 1 when someone in the elevator presses the first or second floor buttons, respectively. The inputs CALL1 and CALL2 are 1 when someone on the first or second floor presses the elevator call button. The inputs FS1 and FS2 are 1 when the elevator is at the first or second floor landing. The output UP turns on the motor to raise the elevator car. The output DOWN turns on the motor to lower the elevator. If neither UP nor DOWN is 1, then the elevator will not move. R1 and R2 reset the latches (described below); and when DO goes to 1, the elevator door opens. After the door opens and remains open for a reasonable length of time (as determined by the door controller mechanism), the door controller mechanism closes the door and sets DC = 1. Assume that all input signals are properly synchronized with the system clock.

Please apply the following guidelines to your design.
If you were to realize an elevator controller that responded to all of the inputs FB1, FB2, CALL1, CALL2, FS1, FS2, and DC, you would need to implement logic equations with nine or more variables (seven inputs plus at least two state variables). However, if you combine the signals FBi and CALLi into a signal Ni (i = 1 or 2) that indicates that the elevator is needed on the specified floor, you can reduce the number of inputs into the control circuit. In addition, if the signal Ni is stored so that a single pulse on FBi or CALLi will set Ni to 1 until the control circuit clears it, then the control circuit will be simplified further. Using a D flipflop and a minimum number of added gates, design a storage circuit that will have an output 1 when either input (FBi or CALLi) becomes 1 and will stay 1 until reset with a signal Ri.
Using the signals N1 and N2 that indicate that the elevator is needed on the first or second floor (to deliver or pick up passengers or both), derive a state graph for the elevator controller. (Only four states are needed.)
Realize the storage circuits for N1 and N2 as describe in the design specification.

Reference no: EM13345859

Questions Cloud

At a given instant in time flywheel oa is caused to rotate : at a given instant in time flywheel oa is caused to rotate with angular velocity of w2radsec and angular acceleration o
Consider a sinusoidal wave with frequency of 300khz as a : consider a sinusoidal wave with frequency of 300khz as a carrier signal. we want to transmit a sinusoidal signal with
Calculate the enthalpy entropy and gibbs free energy : a.calculate the enthalpy entropy and gibbs free energy changes when 10g of supercooled liquid silver solidifies
If 100 ml of 005m nacl is added to 2000 ml of solution : solid nacl is added slowly to a solution containing 0.10 m agno3 and 0.20 m pbno32. ksp for agcl is 1.8x10-10. ksp for
The block diagram for an elevator controller for a : the block diagram for an elevator controller for a two-floor elevator follows. the inputs fb1 and fb2 are 1 when
In a reaction where pbcl2 precipitate was formed using : in a reaction where pbcl2 precipitate was formed using pbno33 and hcl explain why the pbcl2 precipitate dissolved when
At 250degc a sample of xe gas occupies 550 ml in a : at 25.0degc a sample of xe gas occupies 550 ml in a piston-cylider apparatus when the external pressure is 353 torr. at
An insulated piston-cylinder device contains 2l of : an insulated piston-cylinder device contains 2l of saturated liquid water at a pressure of 150kpa-which is constant
Discuss the pros and cons of the various methods of : discuss the pros and cons of the various methods of application of solid fertilizers. describe the revelant facets of

Reviews

Write a Review

Electrical Engineering Questions & Answers

  How does the placement location of ecg leads affect signal

How does the placement location of ECG leads affect the signal measured Why is the placement of ECG leads on the wrists equivalent to placing them on the chest

  Determine at what frequency will the gain be down by 3db

Attach a capacitor of value 0.001μF in parallel with the feedback resistor of your non-inverting amplifier. At what frequency will the gain be down by 3dB. Draw and design a non-inverting amplifier with a gain of 6 V/V.

  Determine the settings

Determine the settings Z1, Z2 & Z3 for the relay at B12.

  Design a 3-bit counter using d flip-flops

Design a 3-bit counter using D flip-flops to cycle through the following sequence: 010, 101, 110,001. Make sure the counter is self-starting.

  What is the built in potential of the silicon diode

A silicon diode has a doping profile such that ND = ax3. What is the depth of the junction assuming the p side is uniformly doped with NA per cubic cm. Assume the x origin is at an ideal ohmic contact on the n side of the diode.

  Design the counter assuming the outputs come directly

A) Design the counter assuming the outputs come directly from JK flip-flops. B) and design the counter assuming a two-stage binary counter is used with the JK flip-flop output decoded

  What are the applications and classifications of compressors

What are the applications,classifications,design,energy conversion principles involved,maintenance and fault of compressors

  What are the boundary conditions of the normal components

What are the boundary conditions of the normal and tangential components of steady current at the interface of two media with different conductivities

  Define and draw the frequency response

What are the techniques used to make feedback system stable? Explain and draw the frequency response of a 1-pole feedback amplifier.

  Write a function averaging that performs smoothing

function [y,m] = averaging(x, n, N) where "y" is the output sequence, "m" is the corresponding index vector, "x" is the input sequences with index vector "n", and "N" is the order of the averaging filter.

  Find the impulse response h for the system

1. Find the system transfer function H(z). 2. Find the impulse response h(n) for the system. 3. Find the inverse transfer function H-1(z). 4. Find the impulse response h(n) for the inverse transfer function H-1(z). 5. Is the system described by H-..

  Determine the maximum number of hopping frequencies

An FH-BPSK signal modulated with 6kbps data has a spectrum bandwidth of 20 MHz. the BPSK signal is filtered allowing only two spectral components on either side of the carrier find the maximum number of hopping frequencies.

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd