How to solve : synchronous motor connted to infinite bus over short feeder with purely reactive impedance. Drawin P' - Delt ' characteristics showing A1 and A2 areas.
Suppose that a family of logic gates considers the input ranges of [0 - 0.2V] as "0" and [3.1V-3.5V] as "1". 1. What are the reasonable output ranges for "0" and "1" (a) "0": [0.0 - 0.1V], "1": [3.2V - 3.5V];
For input signal voltages between these limits, the input should pass unaltered to the output. The peak current drawn from the input source may not exceed 1mA. You may use any circuit component we've studied except opamps.
a curve of radius 159 m is banked at an angle of 11deg. an 810-kg car negotiates the curve at 93 kmh without
A radio channel has a bandwidth of 10 KHz and a SNR of 15 dB. What is the maximum data rate that can be transmitted: (a) Using any system (b) Using a code with 64 possible states
part-1q 1. for the circuit shown determineathe time constant when the switch moves to position 1bthe mathematical
Three parts of asingle-phase electric system are designated A,B and C and areconnected to each other through transformers. Neglect transformerresistance and magnetizing current. The transformers are rated as follows
A capacitor, an electric resistance heater, and an impedance are connected in a parallel to a 120 volts, 60Hz system. the capacitor draws 50VARs, the heater draws 100 watts and the impedance coil draws 269 VA at a power factor. Find the Apparent P..
Llooking at the distribution transformers failure trend it shows a high rate in wet season than in the dry seasons. what could be the likely contributing factors
In RCL circuit connect with A.C. voltage, Inductor and capacitor increase thier voltage. For example Circuit connect with 230 V A.C. Voltage and frequency 4.96Hz. Inductor and capacitor's Vrms value become 1400V.
write a program to compute the power loss in a transmission line with a resistance of .05ohms/mile. compute the power loss if 500kw of power is transmitted from a power generating station to cities at distances of 20, 30, 40, 50,...100 miles at 10..
Design (simulaton, analysis), build and test an op-amp based instrumentation amplifier with the following specifications: (a) Have very high input resistance (minimum is 1 Mega Ohm). (b) Have very high voltage gain (minimum 1000V)
The line voltage and current delivered to a balanced 3-phaseWye- connected resistive load bank is measured and found tobe 415 V and 30 A respectively. 1) What is the value of voltage across on phase of the loadbank