A bidirectional shift register is one in which the datacan be shifted either left or right. It can be implemented by usinggate logic that enables the transfer of a data bit from one stageto the next stage to the right or to the left, depending on thelevel of a control line. A 4-bit bidirectional shift register isshown in Figure below. A HIGH on the RIGHT / LEFTcontrol input allows data bits inside the register to beshifted to the right, and a LOW enables data bits inside theregister to be shifted to the left.
Determine the state of the shift register given above after each clock pulse for the givenRIGHT / LEFTcontrol input waveform in figure below. Assume that initiallyQ0 = 1, Q1 = 1, Q2 = 0,Q3 = 1 and serial data- input line is LOW.
Note: State of the shift register means you have to drawonly the wave forms for Q0, Q1, Q2and Q3.
We want to sample the 2-D continuous signal f(x,y)=exp{-\(pi(x^{2}+y^{2})\)} by means of a rectangular sampling scheme to obtain 1.5 samples per millimeter. Determine the PSF h(x,y) of an ideal low pass anti aliasing filter
A sequential circuit hast two inputs (w1 and w2) and one output (z). Its function is to compare the input sequences on the two inputs. If w1 = w2 during any four consecutive clock cycles, the circuit produces a z=1
Calculate the impedance to neutral of this line. Calculate the line charging current in A/phase if the line is 100 km long and is operated at line-line voltage of 230 kV (8.565 pF/m, j3.23 micro-Siemens/km, 42.9 A/phase)
The thermostat contacts are set to close at 50, 60, 70 and 80 degrees Fahrenheit, respectively. The PLC ladder logic program is to designed so that a temperature below 50 degree F, three heaters are be to be on. Between 50 60 60 degree F two heate..
Three identical inductors are connected in series to a 240v 1000hz line, and the circuit current is .6A What is the inductance of each inductor
Assume dual rail logic. Dual rail logic means that both a variable and its complement are available as inputs to the logic block, such that an inverter is not needed to generate B' from B.
A current of 5A flows through a resistor connected in series with choke coil. It is supplied with 250 V , 50Hz supply . If potential difference across resistor is 125 and across choke coil is 200 volt .
A process has the dynamics G(s)=5/s^2. Design a unity negative feedback controller of the form G.c(s)=Ks+1 for a step response exhibiting approximately 15% overshoot.
An Electric Range top burner control adjusts the duty cycle of the current and voltage supplied to surface heating element as a function of the control's dial setting. The range controller operates from a 240 VRMS single phase supply
A certain inverting amplifier has a closed-loop gain of 25. The op-amp has a open-loop gain of 100,000. If another op-amp with an open loop gain of 200,000 is substituted in the configuration, find the new closed-loop gain.
Begin with a breadboard, wire, an RGB LED and some resistors. Using the forward voltages given in the RGB LED datasheet, calculate the correct current-limiting resistors needed to light each color of the LED (assuming VDD = +5V).
Calculate the unit step response of the DT systems with the following impulse responses: a-) h[k]= u[k+6]- u[k-10] b-) h[k]= 3^k- u[-k]
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!