Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
A factory has an electrical load of 1,800kW at a lagging power factor of 0.6. An additional variable power factor load is to be added to the factory. The new loaf will add 600kW to the real power load of the factory. The power factor of the added load is to be adjusted so that the overall power factor of the factory is 0.96 lagging.a) Specify the reactive power associated with the added load?
b) Does the added load absorb or deliver magnetizing vars?
c) What is the power factor of the additional load?
d) Assume that the rms voltage at the input of the factory is 480 V. What is the rms magnitude of the current into the factory before the variable power factor load is added?
e) What is the rms magnitude of the current into the factory after the variable power factor load has been added?
A black box contains an impedance coil across the two available terminals of the box. The box 20 ampere from a 12-V battery and when it is connected to a 220-v 60 cycle source, it takes 900W.
Suppose you have a 2 kW electric heater rated for 220 volt operation, which you intend to operate at a reduced power dissipation of 1kW. Calculate the proper amount of voltage you would need to achieve this reduced power dissipation
four determinations of the pH of a certain solution are 7.90, 7.94, 7.91, and 7.93. Assuming normallity of determinations with mean mhu, standard deviation sigma, find: A. 99% confidence interval for mhu "u"
A three-phase synchronous generator (Delta-connected) rated at 10KVA, 230 V, has a synchronous reactance of 1.2ohms per phase and an armature resistance of 0.5ohms per phase. (a) Draw the phasor diagram.
Also assume the house power wiring Has the two wires routed around the floor and ceiling. Determine the induced voltage at the power input to a digital computer that is connected to the power net for a lightning channel 1 km away.
Determine the decimal value of each of the following SIGNED binary number displayed in the 2's complement form: a. 10011001 b. 01110100 c. 10111111
An AM broadcast receiver's pre-selector has a total effective Q of 90 to a received signal at 1180 kHz and uses an IF of 455 kHz. Calculate the image frequency and its dB of suppression.
The configuration is shown in Figure 6.5. Use six LEDs as shown in Table 6.1 to represent the outputs. The Time in This State can be met in several ways. One method is to use a debounced switch as input, another to input a 1 Hz clock.
Consider the first-order linear differential equation y(t) + 5 (dy(t) / dt) = x(t) Compute the zero-input response (general solution of the homogeneous equation) to find the system-specific part of the response
noncausal, linear, and time-invariant. Determine the impulse response for the system and verify that an LTI system defined by the impulse response you determined satisfies the difference equation.
Design a combinational circuit with four inputs, x,y,w, and z, and four outputs: A, B, C, and D. When the binary input value in decimal is 3,5,6,9,10 or 12, the binary output value is one less than the input value, otherwise it is one greater than..
Suppose that the machining operation requires 1 kW, that the tool machine ihas 90 percent efficiency, and that the supply current is 14 A rms with a power factor of 0.8. Find the AC machine efficiency.
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd