Shell-and-tube heat exchanger is used to cool flow of steam

Assignment Help Mechanical Engineering
Reference no: EM13711598

A shell-and-tube heat exchanger is used to cool a flow of steam using a stream of cooling water. The steam enters the heat exchanger at 0.1 bar and a quality of 91% (state 1), and exits as a saturated liquid at the same pressure (state 2). The mass flow rate of the steam is 2.6 · 105 kg/hour. The cooling water enters the heat exchanger at 5 MPa and 15oC (state 3) and exits at 38oC at the same pressure (state 4). The cooling water can be treated as an incompressible liquid. Neglect stray heat transfer and neglect kinetic and potential energy effects. As well, assume the system is operating under steady-state conditions.

a) Determine the mass flow rate of cooling water in kg/s.

b) Determine the rate of heat transfer between the steam and the cooling water in MW.

Reference no: EM13711598

Questions Cloud

Range of projectile and velocity on impact given inputs : (MATLAB) given a cannon ball that is shot upwards at an angle, the time taken for the cannon ball to hit the ground is: Write a single function that outputs the total time of flight, range of projectile and velocity on impact given inputs. Use the fu..
A woman is admitted to the emergency room : A woman is admitted to the emergency room because the tissues in her legs are retaining water. She is diagnosed with severe pitting edema-any pressure applied to the swollen tissue leaves a temporary indentation or "pit" in the tissue, even wh..
What is coefficient of restitution needed for good ammo : A "pumpkin chucker" designed for the annual pumpkin competition held near Millsboro, delaware every fall (first week of November) uses a pneumatic launcher (air cannon) to throw its pumpkin. It is important to know if your "ammunition", the pumpkin, ..
Difference between causes and effects in the swot analysis : Difference between causes and effects in the SWOT analysis.Causes are important, not effects. Once the SWOT Analysis is created, each group needs to construct the SWOT Bivariate Strategy Matrix.
Shell-and-tube heat exchanger is used to cool flow of steam : A shell-and-tube heat exchanger is used to cool a flow of steam using a stream of cooling water. The steam enters the heat exchanger at 0.1 bar and a quality of 91% (state 1), and exits as a saturated liquid at the same pressure (state 2). The mass f..
Briefly explain how gmos are created : Briefly explain how GMOs are created in your own words.
Fire truck draws water from an open constant-level reservoir : A fire truck draws water from an open constant-level reservoir through a hose of 0.2 ft2 cross section. The water is discharged from the pump through another 0.2 ft2 hose to a surge tank pressurized to 120 psig with air at the top. The pump adds 970 ..
Determine volume and height of cooling tower-effectiveness : A counter flow cooling tower cools 2000 gal/min water from 104 F to 85 F with 210,000 ft^3/min of air at 90 F Dry bulb Temperature and 76 F WBT . The Mass transfer coefficient -surface area product is hA= 123lbm/hr ft^3. Air mass flow rate per unit c..
Strained juice is concentrated in a vacuum evaporator : In a process for concentrating 1000kg of freshly extracted orange juice containing 12.5 wt% solids, the juice is strained, yielding 800kg of strained juice and 200kg of pulpy juice. The strained juice is concentrated in a vacuum evaporator to give an..

Reviews

Write a Review

Mechanical Engineering Questions & Answers

  Room b has 15 kg air at 20 degrees celsius both rooms at

a rigid insulated container has two rooms seperated by a membrane. room a contains 1 kg air at 200 degrees celsius and

  Air at 35c 1 atm and 50 relative humidity enters a

air at 35c 1 atm and 50 relative humidity enters a dehumidifier operating at steady state. saturated moist air and

  A full-revolution press has 100 rpm flywheel rotation the

a full-revolution press has 100 rpm flywheel rotation. the press is equipped with two-hand palm buttons mounted on the

  Air enters a compressor at 100 kpa and 300 k and is

1. the adiabatic compressor of a large gas turbine receives air from the ambient surroundings at 95 kpa and 20degc

  Strained juice is concentrated in a vacuum evaporator

In a process for concentrating 1000kg of freshly extracted orange juice containing 12.5 wt% solids, the juice is strained, yielding 800kg of strained juice and 200kg of pulpy juice. The strained juice is concentrated in a vacuum evaporator to give an..

  The steam then enters the second stage and exits at 147

a well-insulated turbine operating at steady state has two stages in series. steam enters the first stage at 800

  What happens if a positive edge dislocation meets a

what happens if a positive edge dislocation meets a negative edge dislocation on the same slip plane with a parallel

  Calculate the exact integration result using matlab

Calculate the exact integration result using Matlab symbolic tools and calculate the errors in calculating work done

  The prizes are all the same so the order in which the

at a certain event 16 people attend and 5 will be chosen at random to receive door prizes. the prizes are all the

  Calculate the convective heat transfer coefficient

air at a pressure of 200 kpa and free stream temperature of 27 degc flows over a square plate at a velocity of 30 ms.

  Given that the elastic modulus and poissons ratio of the

a cylindrical bar of metal having a diameter of 18.4 mm and a length of 192 mm is deformed elastically in tension with

  Determine the mass flow rate at the inlet

Steam at 80 bar, 440 0C, enters a turbine operating at steady state at a volumetric flow rate of 180 m3/min. The water exits the turbine in two streams, 20% as exits through a 0.25 m diameter pipe at 60 bar, 400 0C. The rest exits through a 1.5 m dia..

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd