Project on LFC using tuned FOPID. I have considered a two area model. Need help regarding implementation of GA MATLAB code for a two area interconnected power system for LOAD FREQUENCY CONTROL.
Create a simulation model for the same and getting the output after PID Implementation. Now in order to decrease the overshoot and settling time of the output wave of PID Implement the GA technique to get the optimized result.
Download:- two.rar
Find the surge impedance load and based on the practical line loadability determine the number of three phase,60 Hz lines required to transmit this power, with one line out of service.
Suppose you have a set of 10 symbols. Assume that in an average text each symbol appears as frequently as any other. (i) What is the relative frequency of each symbol (ii) What is the entropy of this symbol set
Algebraically prove the following equation. Identify by name the boolean algebra identity used in each step. Hint: Use consensus 4 times. WY+YZ'+WXZ+W'XY'=WY+YZ'+W'XZ'+XY'Z
Write an instruction sequence to subtract the 4-byte number stored in memory locations 0x10-0x13 from the 4-byte number stored in memory locations 0x00-0x03 and store the difference in memory locations 0x20-0x2
The generator is delivering 48 MW to the bus bar at the rated voltage with its field current adjusted for a generated emf of 46 kV per phase. Determine the armature current and the power factor. State whether power factor is lagging or leading
Two infinitely long coaxial cylindrical surfaces, r = a and r= b (b > a), carry surface charge densities ρsa and ρsb,respectively. (a) Determine the electric field intensity everywhere.
In a 50 KVA, Y connected, 440 V, 3 phase, 50 Hz alternator, the effective armature resistance is 0.25 ohms per phase. Synchronous reactance is 3.2 ohms per phase. Determine at rated load and unity power factor,
A clever student notices that a high constant loop gain would make the PLL converge in frequency and phase. Rather than use an amplifier with infinite gain the student decides to just use an unstable filter.
suppose a transmission channel operates at 10 mbps and has a bit error rate of 10-2. bit errors occur at random and
The odd cycle sequences1,3,5,7, and repeats. An external input selects which cycle to perform. An input of 0 selects the even cycle and an input of 1selects the odd cycle. The cycles can be entered and exited throughstates 0 and 1.
Two generators are connected in parallel to the same bus bar and each has an inductive reactance of 10% on rating. Generator 1 is rated 2,500 kVA and 2.4 kV, and generator 2 is rated 5,000 kVA and 2.4 kV.
Derive the three-term error correction formula. Include the appropriate signal flow graphs in all of your derivations. Hint: The one-term and both two-term error models are simplifications of the threeterm error model.