Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
A plate-tin heat exchanger is used to condense a satu-rated refrigerant vapor in an air-conditioning system. The vapor has a saturation temperature of 45°C, and a condensation rate of 0.015 kg/s is dictated by system performance requirements. The frontal area of the condenser is fixed at Afr, = 0.25 m2 by installation requirements, and a value of hfg = 135 kJ/kg may be assumed for the refrigerant.
(a) The condenser design is to be based on a nominal air inlet temperature of Tc,i = 30°C and nominal air inlet velocity of V = 2 mis for which the manufacturer of the heat exchanger core indicates an overall coefficient of U = 50 W/m2. K. What is the corresponding value of the heat transfer surface area required to achieve the prescribed condensa¬tion rate? What is the air outlet temperature?
b) From the manufacturer of the heat exchanger core, it is also known that U ∞ V0.7. During daily operation the air inlet temperature is not controllable and may vary from 27 to 38°C. If the heat exchanger area is fixed by the result of part (a), what is the range of air velocities needed to maintain the prescribed condensation rate? Plot the velocity as a function of the air inlet temperature.
Random Diffusion - Provide all relevant equations The stability of the numerical method (ex: if you change the delta or delta x, does your result change.) Change something and see the effect it has.
using the fact that the tension in the rope must remain constant in all sections of the rope calculate the total force
air enters an ideal diffuser operating at steady state at 1 bar -3degc and 260 ms and exits at with a velocity of 130
an electrical power plant has stack gases exhausting at 150 degree c. design a basic rankine cycle that uses water
a 1-kg disk slides on a smooth horizontal table and is attached to a string that passes through a hole in the table.a
ateam at 5 bar 320 c enters a steady state turbine with a volumetric flow rate of 0.65m3s and evpands adiabatically to
a 14 mm diameter 50 mm long mild steel rod undergoes a stress test. a tensile force of 18800 n is applied and the rod
a steam power plant utilizing the rankine cycle has the following particulars- steam pressure and temperature at inlet
For a control volume including the turbine and a portion of its immediate surroundings so that the heat transfer occurs at the ambient temperature, 40°F, determine the rate of entropy production in Btu/ °R per lb of air passing through the turbine..
An air compressor operates under steady conditions. Air is compressed from an initial state of 295 K and 101 kPa to a final state of 430 K and 340 kPa. Ignore heat transfer between the compressor and surroundings and ignore kinetic energy and potenti..
Refrigerant 134a at 30 lbf/in.2, 408F enters a compressor operating at steady state with a mass flow rate of 150 lb/h and exits as saturated vapor at 160 lbf/in.2 Heat transfer occurs from the compressor to its surroundings, which are at 408F. Cha..
.How does data screening differ from data cleaning?
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd