A low pass filter has a cut-off frequency of 8 kHz and a high pass filter has a cut-off frequency of 5 kHz. These two circuits are connected back to back in cascade to form an input-output system. How does this combination work, band pass or band stop?
An LED is rated at VF = 1.6 Volts to 2.0 Volts at IF = 20 mA. What value of series resistance is needed to limit the LED current to 20 mA when this LED is connected to a 32 Volts peak source
Discuss the factors that determine transformer efficiency. What are some sources of transformer losses and how can these can be reduced
encounter a sequence of birds while walking in the park. The birds can either be blue (B) or red (R). We let X be the random variable corresponding to the number of birds we encounter until seeing the first blue one.
design a 3-bit synchronous counter (using only D-flip flops and NAND gates) that produces the sequence 000, 010, 011, 001, 101, 100, 000, etc. whenever the single input is 1. The counter retains its current value whenever the input bit is 0.
The silicon cube you were shown consisted of 4x4x4 unit cells. You were shown one dopant in the silicon cube. Given that the lattice constant of silicon is 0.543 nm. Calculate the dopant density represented by the 4x4x4 silicon cube simulation.
The load on a 460-V, 60-Hz, Y-connected, balance three-phase source consists of three equal Y-connected impedances of 100+j100 ohms, and three equal Delta-connected impedances of 300-j300 ohms. Compute the line current, power, and power factor for..
For a photovoltaic installation at latitude 30°N, you have the option to position the panels facing south at slope angles of 0°, 10°, 30°, or 90° to the horizontal plane. Determine the panel orientation you would choose to obtain maximum energy
A 1500 hp phase ac motor load has a power factor of 0.7. What capacitor (in Farads) is required to correct the power factor to 0.90 if the line voltage is 2400 volts The capacitor bank is to be delta connected.
With V=100V, the instantaneous power into a network N has a maximum value 1500 W and a minimum value ?247 W. (1) Find a possible series RL circuit equivalent to N. (2) Find S=P+jQ into N.
Assuming that the scores are normally distributed and the standard deviation for the scores is 80, find the probability that a randomly selected business graduate student at this school has a GMAT score over 700.
A three-phase transmission line is 80 mile long and serves a load of 250 MW at 220 KV and 0.8 power factor lagging. The A, B, C, D constants for the line in each phase are: Determine the sending end voltage and current
Design a summing amplifier that produces an output Vout = (5/2)V1+(5/3)V2 - 4V3 . Draw the complete schematic and pick the appropriate component values. The smallest resistor in the circuit should be R