A counter flow cooling tower cools 2000 gal/min water from 104 F to 85 F with 210,000 ft^3/min of air at 90 F Dry bulb Temperature and 76 F WBT . The Mass transfer coefficient -surface area product is hA= 123lbm/hr ft^3. Air mass flow rate per unit cross sectional area of the cooling tower is [(mdot)a /A ]=1800 lbm/hr ft^2. Determine the volume and height of the cooling tower, effectiveness and relative humidity.
a freezer is 1m wide and deep and 2m high and must operate at -10c when the ambient air is at 30c. what thickness of
an alcohol manufacturing facility emits air with 500 ppm ethanol. the air flows out several roof vents at a total flow
assume that all of the unit cells of a piece of aluminum with dimensions 4in x 4in x 0.001in are arranged so that a0 is
A fire truck draws water from an open constant-level reservoir through a hose of 0.2 ft2 cross section. The water is discharged from the pump through another 0.2 ft2 hose to a surge tank pressurized to 120 psig with air at the top. The pump adds 970 ..
1. a diesel cycle operates with a compression ratio of 15 and a cutoff ratio of 2.5. what is the rate of heat input
A piston-cylinder setup filled with air, initially at 27 °C, 1 bar, changes to 17 °C, and 0.9 bar. Determine, as a present, the change in volume of the air from its initial volume. (in %)
a flow of 2 kgs of saturated liquid r-134a at 200 kpa is mixed with 3 kgs of r-134a at 200 kpa and 10?c. the liquid and
In our stress calculation example, we had an array of rod diameters and wanted to calculate the normal stress in each rod when it is loaded by an axial load P of 1000 lbs. EDU stresscalc ?
large cylindrical bales of hay used to feed livestock in the winter months are d2m in diameter and are stored
nitrogen n2 initially occupying 0.5 m3 at 1.0 bar 20 degree c undergoes an internally reversible compression during
a solar collector receives solar radiation at a rate of 0.315 kw per m2 and delivers the heat to a storage unit whose
a rigid well insulated container is outfitted with a moveable but frictionless partition that separates two sides but