Heat exchanger required to achieve the desired heating

Assignment Help Mechanical Engineering
Reference no: EM13719025

A counter-flow double pipe heat exchanger is heat water from 20 degrees Celsius to 80 degrees Celsius at the rate of 1.2 kg/s. The heating is to be accomplished by geothermal water available at 160 degrees Celsius at a mass flow rate of 2 kg/s. The inner tube is thin-walled and has a diameter of 1.5 cm. if the overall heat transfer coefficient of the heat exchanger is 649 W/m2K, determine the length of the heat exchanger required to achieve the desired heating.

Reference no: EM13719025

Questions Cloud

Explain how you define the times of sunrise and sunset : Explain how you define the nodes xk that represent the dates above - Define a global interpolating polynomial Pr that passes through all data points given for the time of sunrise.
Diameter impeller of a radial-flow water pump rotates : A 400-mm-diameter impeller of a radial-flow water pump rotates at 120rad/s and has a discharge of 0.5m3/s. Determine the discharge for a similar pump that has an impeller diameter of 100mm and operates at 90rad/s.
Engine assuming gallon gasoline produces : As a 75 slug car travels along a horizontal, 3200 ft section of road, it changes speed from 5 mph to 60 mph. During this acceleration, how efficient is the car's engine assuming 1 gallon gasoline produces 120 MJ of energy when completely combusted in..
Temperature of the refrigerant exiting the compressor : Refrigerant R134a is compressed under steady conditions from a saturated vapour at 100 kPa to 500 kPa. The compressor’s isentropic efficiency is 85%. Heat losses from the compressor can be ignored, as can kinetic energy and potential energy effects.
Heat exchanger required to achieve the desired heating : A counter-flow double pipe heat exchanger is heat water from 20 degrees Celsius to 80 degrees Celsius at the rate of 1.2 kg/s. The heating is to be accomplished by geothermal water available at 160 degrees Celsius at a mass flow rate of 2 kg/s.
Counter flow double pipe heat exchanger is to heat water : A counter flow double pipe heat exchanger is to heat water from 20 degrees Celsius to 80 degrees Celsius at the rate of 1.2 kg/s. The heating is to be accomplished by geothermal water available at 160 degrees Celsius at a mass flow rate of 2 kg/s.
Double-tube counter flow heat exchanger : Hot oil is to be cooled in a double-tube counter flow heat exchanger. The copper inner tubes have a diameter of 2 cm and negligible thickness. The inner diameter of the outer tube (the shell) is 3 cm. Water flows through the tube at a rate of 0.5 kg/..
Determine rate of heat transfer per unit width from plate : Consider atmospheric air at 25 degrees Celsius and a velocity at 25 m/s flowing over both surfaces of a 1 meter long flat plate that is maintained at 125 degrees Celsius. Determine the rate of heat transfer per unit width from the plate for values of..
Determine the volume flow rate of the extraction flow : Steam at 3 MPa, 400C enters a turbine with a volume flow rate of 5 m^3/s. An extraction of 15% of the inlet mass flow rate exits at 600 KPa, 200C. The rest exits the turbine at 20KPa with a quality of 90% and a velocity of 20 m/s. Determine the volum..

Reviews

Write a Review

Mechanical Engineering Questions & Answers

  An air-conditioning unit with a coefficient of performance

an air-conditioning unit with a coefficient of performance of 2.93 provide 5000 btuh of cooling while operating during

  The outer spring has d 50 mm d 9mm and n 5 the inner

two concentric helical compression springs made of steel and having the same length when loaded and when unloaded are

  If the specific ratio is the same what is the compression

consider an air-standard brayton cycle. what is the efficiency of the brayton cycle if the pressure ratio is 20 and the

  Changes made to stainlees steel piping to reduce

changes made to stainlees steel piping to reduce intergranular stress corrosion cracking describe four modifications

  Develop a vba program that can determine numericlly

develop a vba program that can determine numericlly integral of any given set of data points using combination of

  The constraint is that the stress created by the

a material is sought for a high speed centrifuge. the objective is to acheive as high an angular velocity w of the

  A 25 mm diameter uniform steel shaft is 600 mm long between

a 25 mm diameter uniform steel shaft is 600 mm long between bearings.a find the lowest critical speed of the shaftb if

  Calculate the final temperature of the system neglecting

a 0.075 kg ice cube at 0 degree c is dropped into an insulated styrofoam cup holding 0.33 kg of water at 25.0 degree c.

  What are the corresponding values of tensile strength yield

a cylindrical steel rod 0.5 in diameter is cold worked to reduce the area. the new diameters in 3 cases are 0.43in

  Find the equal annual payment series that would be

find the equal annual payment series that would be equivalent to the following increasing series of payments if the

  A 100 kva 3- phase star- connected transformer has a

a 100 kva 3- phase star- connected transformer has a primary voltage of 11000 v and a secondary voltage of 440 v and it

  Find the velocity of the final system

If the bullets stick to the block and they move together find the velocity of the final system and find the total impulse of each bullet if the movement takes 0.5s before coming to a stop.

Free Assignment Quote