A free particle has kinetic energy equal to 35 eV.
a) What is the velocity of the particle?
b) If this velocity is known to within 0.2% accuracy, what is fx of the position that particle? Assume that the mass of the particle is 2 x 10-26 kg. Use h and give the answer in nm.
find the voltage E and the current Ir and IL in phasor form
Each pole of a 100kW, 250v flet-compound generator has a shunt field of 2000 turns and a series field of 7 turns. If the total shunt field resistance is 100 ohms, calculate mmf when the machine operates at rated voltage.
Briefly discuss the impact of electron energy, electron current and target on the Bremsstrahlung generated.
A P=900W electric motor with pf=0.82 lagging is connected to a 240 Vrms 60 hertz source. a) Draw an equivalent circuit showing impedance and phasor values for Vs, R and X. b) Find an Xc value to put in parallel with the motor which corrects the pf to..
In comparing the behaviour of an n-channel MOSFET with a p-channel device having identical geometry and threshold voltage, it is found that the n-channel FET has a greater drain current than that of the p-channel FET.
What kind of wireless networking alternative makes the most sense when considering network links that span an appreciable portion of the globe?
Operation of NPN Bipolar Transistor : a. Describe the operation of a typical NPN bipolar junction transistor used both as an amplifier and a switch. b. List the 4 regions of operation and draw I-V characteristic curve.
A 250hp, 500v dc shunt motor draws a nominal field current of 5A under rated load. The resistance is 90ohms. Calculate the ohmic value and power of the series resistor needed so that the field current drops to 4.5A
Power Systems Theory Definitions and Formulas, Define, (a) The fault level of a system or unit in a system, (b) base MVA
A 3 phase Y connected alternator is rated at 1600 KVA, 13500 V. The armature resistance and synchronous reactance are 1.5 ohms and 30 ohms respectively. Calculate the % voltage regulation for a load of 1280 KW at 0.8 leading power factor.
Briefly explain your ideal job as electrical engineer? Why did you select this career? What goals do you have in this career? How do you plan to get these goals?
Write a ladder logic program needed to implement each of the following (assume inputs A, B and C are all normally open toggle switches).