An inductive load draws 5 kW at a power factor of 0.7 from a 240 V, 50-Hz supply. To reduce the kVA demand charge, the consumer decides to connect a capacitor in parallel with the load. Calculate (i) the parallel capacitance C1 that would be required to change the power factor of the total load on the supply to 0.80 lagging and (ii) find the value of the supply current at this power factor.
A 1 load draws 6 MW at 0.8 power factor lagging. Determine the reactive power required from a parallel capacitor to bring the power factor of the parallel combination up to 0.93
In a Built in Self Test, for a combinational logic system, what are the advantages of using a counter instead of an ALFSR to generate testing vectors for 2 cases.
Energy of a moving charge, A region in space has an Electric field given by E = x(x^) - y(y^) + xy(z^) where (x^), (y^), (z^) indicate corresponding letter with caret on top of it.
A signal, m(t) which is bandlimited to 20 KHz, is going to be transmitted over a channel a) If the stepsize must be less than \(.002 m_{p}\) and the number of steps mut be a power of 2, calculate the minimum number of bits that satisfies this crit..
Let us assume that a synchronouse 3 phase alternator produces a no-load line voltage of 13.2 KV. if a load having a lagging power factor of 0.8 is connected to the machine, must the excitation be increased or decreased
The Finite-Difference Time-Domain (FDTD) method is a computational electromagnetic technique for solving for the electric and magnetic fields in arbitrary spatial domains in the time domain
If we have a 600ohm transmission line terminated with a 1200ohm resistor, how long must the transmission line be if the input impedance is purely real?
Rated voltage is applied to the low voltage winding and the high voltage winding is open-circuited. Under this condition, the current into the low voltage winding is 2.4 A, and the power taken from the 2400 V source is 3456 W.
(a) What is the tension in the coupling between the first car and the locomotive? (b) If this tension is equal to the maximum force the locomotive can exert on the train, what is the steepest grade up which the locomotive can pull the train at 25 ..
A "ferrite" having a relative permeability of 50 H / m, that operates with flux densities sufficiently small, may be considered a single material. If the magnetic flux density in the material is B = 0.05 T, H and M. halle How to compare the values
An LED with a rated range of VF = 1.4 V to 1.8 V at IF = 20 mA is connected to a driver circuit with a peak output of 14V. What value of current-limiting resistor would be needed to limit the LED current to a maximum value of 20 mA
How do the short length and medium length transmission line models differ and why Draw the equivalent circuit of a medium-length transmission line