A 50-Hz synchronous salient pole generator is driven by a hydro-electric turbine at a speed of 125 rpm. There are 576 stator slots with two conductors per slot. The air-gap diameter is 6.1 m and the stator length is 1.2 m. The sinusoidally distributed flux density has a peak value of 1.1 T.
(a) Calculate the maximum rms single-phase voltage that can be produced by suitably connecting all the conductors.
(b) Find the per phase emf if the conductors are connected in a balanced 3-phase winding.
ECE 511: Analog Integrated Circuits Fall 2016 Assignment. Complete the table on the following page related to the operating point for all transistors. This should help in computing the rest of the homework questions. I recommend a spreadsheet for t..
The fault level at the grid connection point is 1000 MVA. What will now be the required rating of circuit breakers connected to the busbars?
If the capacitor in the previous problem has a plate separation of 1 mm, what is the average displacement current, to the nearest tenth of a microamp, during that time period Assume a resistance of 180006 ohms and an applied voltage of 14 volts.
Random variable X is Gaussian with zero mean and variance of 1. Y is defined as Y=X^5. How do I find the probability density function, mean and variance of Y
Given that the required transmission time for a block of data of length 64kilobits to be transmitted error-free is 6 seconds and that the receiver has a bandwidth of 20kHz, what is required SNR of the receiver
A 208-V Y-connected synchronous motor is drawing 50 A at unity power factor from a 208-V power system. The field current flowing under these conditions is 2.7 A. Its synchronous reactance is 0.8Ω. Assume a linear open-circuit characteristic. Fi..
An 8 pole, three phase 50kVA, 220V, Y connected synchronousgenerator has a synchronous reactance of 4.8ohms per phase andoperates in stand-alone. Neglect all loses. The field voltage isadjusted to give rated voltage across the output terminal at n..
What is the conclusion that can be made for linear,square-shapedcells and frequency reuse factors C=3 and C=4 interms of theirSIR(Signal-interference ratio).
Calculate the total amount of time each employee spent on the Web for the week and the total amount of time that company computers were used for this purpose. Rank the employees in the order of the amount of time each spent online.
3-singlephase 2 winding transformers, each rated 500 MVA, 13.8/199.2 kV, with leakage reactance Xeq = 0.10 per unit, are connected to form a three-phase bank. Winding resistances and exciting current are neglected.
A single-phase, half-wave SCR circuit is used to control the power consumption of an inductive load. The resistive component of the load is 5 Ohm. The source voltage is 120 V (rms). When the triggering angle is adjusted to 60 degrees
A half-wave dipole antenna in a PCS handset at 1.9 GHz, requires a signal strength of 0.01 micro volts per centimeter to operate with acceptable performance. The transmit antenna is assumed to be a half-wave dipole, has a cell radius of 5 km.