Three single-phase transformers are used to form a three-phase transformer bank rated 18 MVA, 13.8Δ-120Y kV. One side of the transformer bank is connected to a 120-kV transmission line, and the other side is connected to a three-phase load of 10 MVA at 13.2kV and 0.8 lagging power factor.Using the base in the tranmission line of 120-kV and 20 MVA, find the load impedance in per unit to be used in the line-to-neutral impedance diagram.
A 600V, dc shunt motor has an armature and field resistance of 1.5 ohm and 600 ohm, respectively. When the motor runs unloaded, the line current is 3A, and the speed is 1000 rpm.
The gauge pressure on an air tank is measured to be 250 kPa at the surface of the water. Take the atmospheric pressure to be 100 kPa. The density of water is 997 kg/m3. a) What is the absolute pressure in the tank at the surface
The voltage across a 0.2 H coil is given. What is the sinusoidal expression for the current?
There are 5 inductors in series and they are 1H,2H,3H,4H,5H what is the total equivalent inductance. There are 5 capacitors in series and they are 1F,2F,3F,4F,5F. what is the total equivalent capacitance.
a 10 ohm resistor is connected across a 12 v battery. How much current is there through the resistor?
Build a home security system circuit using this program. The system must include a door sensor,window sensor, smoke detector, water leak sensor, a motion detector.
Analysing an RF splitter and power levels, A splitter is a device that has a single input and several outputs. It is used to send a signal to several different locations
You must design a three axis position indicator for the latest robot arm. Using no more than two operational amplifiers, design a circuit that uses three inputs, v1, v2, and v3 to produce an output signal vo=3 v1-2 v2-5 v3.
The parameters of a certain transmission line operating at ω = 6×108 rad/s are L = 0.35μH/m, C = 40 pF/m, G = 75 μS/m, and R = 17 Ω/m => α=0.0943 Np/m, β=2.2467 rad/m, λ=2.7966 m, Z0 =93.623-j3.6368
Assume that a receiver has a first amplifier stage with a 5KW input resistance, a gain of 300, an input audio signal of 20 mV, and an operating temperature of 27oC. When the amplifier is operating with a bandwidth first of 10 MHz,
1. Two resistors R1 = 5.6 kΩ and R2 = 3.3 kΩ are to be connected in series. Calculate the series equivalent resistance Rs. 2. The same two resistors are reconnected in parallel. Calculate the parallel equivalent resistance Rp.
Plot the signal x(n) 0