A vapor-compression heat pump system uses R-134a as the working fluid. The refrigerant enters the compressor at 0.24 Mpa, 0 degrees Celsius, with a volumetric flow rate of 0.6m^3/min. The compression process is adiabatic to 0.9 MPa, 60 degrees Celsius, and saturated liquid exits the condenser at 0.9 MPa.
Find the following: a.) The power input to the compressor, in kW.
b.) The heating capacity of the system in kW (Qout)
c.) The coefficient of performance
d.) The compressor's isentropic efficiency.
Wind turbines are becoming more and more common as a method of energy production, wind turbines by their very nature are dynamic and are subject to and create their own internal and external kinematics and kinetics.
Determine the rate of heat transfer to the mid-stage cold head and determine the rate of heat transfer to the cold head
Determine Fourier Number, Compare two identical steel spheres, except the first has a two inch diameter while the second sphere has a four inch diameter. The larger sphere will have a Fourier number approximately
Probabilistic Hough transform in big O notation
Effect of pressure on temperature and density of air for an adiabatic process, The pressure is to be raised from atmospheric to 7 psi (4.83 bar). The process is adiabatic, and the volume is constant and unknown.
Classify the sections of the components in automatic control system.
Need a critical review journal paper about the different types of trucks gap and skirts and boat tails
Use Psychrometric chart to determine Latent portion
Design of absorption column and the cooler. Process design of other units should be completed along with pipe sizes.
The system on site is a pressure sand filter, with a service curve. The filter is backwashed using the feed pump, at a higher flow rate, shown as backwash curve. What is the speed of the pump to achieve the service and backwash flow rates ?
Design life is 9630 hours, rotating at 250 rpm, load of 880 lbs, what is the basic design load rating (assuming no axial loads)?
The entrance is inward projecting. What flow will be expected if the gate valve is one-half open?
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd