Evaluate the optimum capacitor value for unity

Assignment Help Electrical Engineering
Reference no: EM131288252

Assignment: Electrical Power Systems

Examine and analysis real, apparent and reactive power components in linear loads?

Evaluate the optimum capacitor value for unity / near unity power factor for power distribution system?

Conduct a series of simulation assessments to determine the power factor in linear and nn linear loads connected at distribution networks ( pspice software or matlab)

Explain your own thoughts, observation for each of the tests above and provide your profesionl comments

An Investigation into the load flow analysis in 7 bus distribution network with and without renewable energy using ETAP software

Key Words: Load flow analysis; distribution network; renewable sources

Software Tools: ETAP

Submission, Format and Process: Research reports will be submitted via Turnitin online submission system via the module area of Course Resources. Submissions need to be made using standard text document using black text on white paper in 11 point font size. Further guidance is available via the Turnitin submission interface.

Description: Load flow study is a numerical analysis of the flow of electric power in an interconnected system. Load-flow studies are important for planning future expansion of power systems as well as in determining the best operation of existing systems. The principal information obtained from the load-flow study is the magnitude and phase angle of the voltage at each bus, and the real and reactive power flowing in each line.

You are required to submit an assignment of 2000 to 2500 words only. Directed studies work introduced in the lecture, laboratory & tutorial sessions will form the basis for most of the assignment topics but you are encouraged to extend the assignment according to your own interests and professional skills development needs and to use the assignment as a platform for becoming more proactive with electrical power system design, analysis, simulation, prototyping, test, validation and wider personal development opportunities.

The assignment must include and explore the following prescribed topics:

(1) Use ETAP software to construct a distribution power network of at least 7 buses. You can start your distribution network at 125 kV and take it down to 0.415 kV (125 kV - 33 kV - 11 kV - 0.415 kV). You should have industrial loads connected to the 11 kV as well as domestic loads connected to the 0.415 kV. It is up to you to select the details of your loads (power and P.F.).

(2) Carry out the load flow study of the network in (1). In your study you should comment on the magnitude and phase angle of the voltage at each bus, and the real and reactive power flowing in each line.

(3) Carry out the load flow studycalculations for at least a two bus network using the Newton-Raphson Method.

(4) Explain your own thoughts, observation for your simulation results and provide your professional comments.

This assignment is designed to support your development as an undergraduate learner and to outline a process of personal verification and evaluation. The purpose of learning is to develop competent graduates that are knowledgeable, creative, has capabilities of design and build skills and vision to bring fresh potential ideas to business. Use this assignment as a first step in redefining yourself as a professional.

In completing this assignment the student will have developed skills in:

• Identify, select, programme and test suitable power flow techniques and algorithms to solve network power, voltage and current distributions

Assignment resources:

- LCUCK Electrical Power Laboratory.
- Lecture, Tutorial and Practical notes available on the university black board
- Reference text books available in the library

Introduction.

It is important to study and analyse the load flow in a network for planning the future expansion of the power systems and also determining the best operation of existing systems. The economical operation of the existing system depends upon knowing the effect of generation dispatch on the loading of transmission lines and transformers and the voltage conditions of various buses of the power system. Load flow study is the determination of the voltage, current, power, power factor and reactive power at different points in power networks under normal operation. The information obtained from studying the load flow is usually the phase angle and the magnitude of the voltage at each bus and the real and reactive power flowing in each line. This include the current in polar or rectangular form. These studies are essential for designing a new power system, the solution obtained from these studies gives the initial conditions of the system for carrying out fault analysis and stability, also to evaluate the transient behaviour of the system. Load flow studies are made on digital computers and in analog computers known as ac calculating board which was a way of doing analysis before using computers. Whether ac calculating board or a digital computer performs the load flow study of a system the data required are the same. The starting point is always a one line diagram. It is important that operating conditions must always be selected for each study. Also at each bus the real power into network must be specified except the bus called usually the swing bus and is the bus to which the power generator is connected. The other buses are classified as load bus and voltage controlled bus. Of course the net power flow to the system could not be fixed in advance at every bus because the loss in the system is not known until the study is complete.

Nowadays exists a number of software implementation of power flow studies and these software implementation perform other types of analysis such as short-circuit fault analysis and economic analysis. Some software use linear programing to find optimal power flow, the condition which gives the lowest cost for power generated.

For this assignment the use of ETAP is implemented to study the power flow in the power system and Newton Raphson solution method will be used for the solutionof the resulting nonlinear system of equations.

Use ETAP software to construct a distribution power network of at least 7 buses. You can start your distribution network at 125 kV and take it down to 0.415 kV (125 kV - 33 kV - 11 kV - 0.415 kV). You should have industrial loads connected to the 11 kV as well as domestic loads connected to the 0.415 kV. It is up to you to select the details of your loads (power and P.F.).

Reference no: EM131288252

Questions Cloud

Examples of economies and diseconomies : Provide and discuss some examples of economies and diseconomies of scale in a college environment. Discuss some forecasting issues that you encounter in your daily life. How do you make your forecasts? Provide some examples of time series that exhibi..
What are the distinguishing characteristics of services : What are the distinguishing characteristics of services? Explain why these characteristics make it difficult to sell services in foreign markets.
Characteristics of a good international brand name : What are the characteristics of a good international brand name?- What are the major causes of international price escalation? Suggest possible courses of action to deal with this problem.
Prepare a report on source of revenue : Prepare a report on Source of Revenue : An Increase in the Medicare Patient Population and Give the Answer of follwing Question:How many more visits will the company generate if it accepts Medicare patients?
Evaluate the optimum capacitor value for unity : Examine and analysis real, apparent and reactive power components in linear loads? Evaluate the optimum capacitor value for unity / near unity power factor for power distribution system?
Estimate the roi-cost-benefit analysis : Why is it important for trainers to be able to estimate the ROI, cost-benefit analysis, and break-even analysis? Give three reasons why calculating this information will assist the training endeavors.
Training return on investment : Training return on investment (ROI) is a calculation of economic return on a project. Refer to the lecture for the formula. Review this problem.
What methods can be used to compute a transfer price : What methods can be used to compute a transfer price (for transactions between affiliated companies)?- Why is it often difficult to compute fair arm's-length transfer prices?
Significant events relating to the grant : Grants are not necessarily recognized as revenue when they are awarded. Columbus City was awarded a state reimbursement grant of $150,000 to assist its adult literacy program. The following were significant events relating to the grant: a. The city, ..

Reviews

Write a Review

Electrical Engineering Questions & Answers

  Calculate the dc voltage before and after encoding

Write the 30-bit sequence that will be transmitted if the encoder receives the bit sequence 00000316.

  What heat sink temp is necessary to ensure safe operation

A power transistor for which Tjmax=180degrees Celsius can dissipate 50Watts at a case temperature of 50degrees. If it is connected to a heat sink using an insulating washer for which the thermal resistance is .6degrees Celsius/Watt

  Why the spiral cable is better than the straight one

Why the spiral cable is better than the straight one? How can I protect my cable to be work for long while? How can we fix the cables when expose to any breaks or cut?

  Determine all minimum sum of products expressions

find all minimum sum of products expressions. ( if there is more than one solution ,the number of solutions is given in parentheses.) label the solutions f1,f2.... a) f(w,x,y,z)= Σm(1,3,6,8,11,14)+Σd(2,4,5,13,15)

  Determine the expected resistance of the material

Assuming the resistance versus temperature function to be linear, determine the expected resistance of the material at 0 degrees celcius( the freezing point of water) and at 100 degrees celcius (the boiling point of water)

  Find the average power dissipated in the soldering iron

The heating element in a soldering iron has a resistance of 30-ohm. Find the average power dissipated in the soldering iron if it is connected to a voltage source of 117 V rms.

  Draw a relay construction diagram

Draw a relay construction diagram and briefly explain the operation of a relay.

  Calculate the end-to-end propagation time delay

A coaxial line 5.6m long has distributed parameters R=6.5ohm/m, L=3.4 uH/m, G=8.4 mS/m, and C=21.5 pF/m. If the line operates at 2MHz, calculate the characteristic impedance and the end-to-end propagation time delay.

  Obtain oscillation frequency at boundary of stability

Design a proportional controller such that the steady state error due to ramp input and sketch the root locus and find the range of values of K guaranteeing stability and obtain using a reasonable approximation the step response of the closed loop sy..

  Find the expression that correctly represent discrete signal

A continuous time system has an output, y, which is given by y= 4sin( 4t+ f /2). It is sampled at a frequency of 4/f Hz. Determine the expression that correctly represent the discrete signal obtained after sampling and its value for n = 1

  Find an exponential model for the situation described

The number of cell phones recycled or refurbished instead of being sent to landfills is increasing by about 30% per year since 2004. In 2008, 5.5 million cell phones were recycled or refurbished. (a) Find an exponential model for the situation desc..

  Calculate values of a and b for imaginary part of poles

a) Evaluate % overshoot, settling time and peak time if a=4 and b=25 b) Calculate values of a&b so imaginary part of poles remains same but real part increased by 2 times

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd