Determine the rate of heat transfer in the cooling section

Assignment Help Mechanical Engineering
Reference no: EM13708236

Moist air at 450C and relative humidity 30% (State 1) with another stream of moist air at 20?C and relative humidity 50% (State 2) in an adiabatic duct. Mass flow rate of dry air is 0.8 kg/s at section 1 and 1 kg/s at section 2. The mixed stream (State 3) is cooled until condensation is about to begin (State 4) at the exit. Temperature of the cooling section boundary is maintained at 5?C. Total pressure is 1 atm throughout the system.

(a) Show the process for moist air on psychometric chart. Label states 1 through 4.

(b) Calculate temperatures (C) of the mixed stream at sections 3 and 4 and relative humidity (%) at section 3.

(c) Determine the rate of heat transfer (kW) in the cooling section.

(d) Find the rate of entropy generation (kW/K) in the cooling section.

Reference no: EM13708236

Questions Cloud

An individual, owns a proprietorship called green : 1. Roger, an individual, owns a proprietorship called Green Thing. For the year 2014, Roger has the following items:-Business income-$200,000.
Determine temperature of air at the exit : At steady state, air at 200 kPa, 325 K, and mass flow rate of 0.5 kg/s enters an insulated duct having differing inlet and exit cross sectional areas. The inlet cross sectional area is 6 cm squared. At the duct exit, the pressure of the air is 100 kP..
Assuming constant specific heats for air at room temperature : A well insulated 3-m X 4-m X 6-m room initially at 7 degrees C is heated by the radiator of a steam heating system. The radiator has a volume of 15 L and is filled with superheated vapor at 200 kPa and 200 degrees C.
Miller-brava is indices in a hexagonal unit cell : Sketch crystallographic planes with the following Miller-Brava is indices in a hexagonal unit cell: (a) 1(Bar)101 ; (b) 2(Bar)112 . Mark the origin and axes. Explain your answers.
Determine the rate of heat transfer in the cooling section : Moist air at 450C and relative humidity 30% (State 1) with another stream of moist air at 20?C and relative humidity 50% (State 2) in an adiabatic duct. Mass flow rate of dry air is 0.8 kg/s at section 1 and 1 kg/s at section 2. The mixed stream (Sta..
Determine the mass of oil in the tank : A curde oil storage tank the tank initially contains 1000m^3 ofcrude oil. Oil is pumped into the tank through a pipe at a rate of 2m^3/min and out of the tank at a velocity of 1.5m/s through another pipe having a diameter of 0.15m. the crude oil has ..
Coaching model : "Coaching Model"   acronym, create your own coaching model, and define the meaning of each letter as it relates to performance management. Specify the primary reasons that you believe your model would be effective. Justify your response.
Develop a preliminary design : Develop a preliminary design, including flow rates, pipe sizes, and pipe slopes for a trunk sewer to be laid in the development shown in the accompanying figure from 6th to 1st Streets along Peavy Avenue
Calculate the pressure at the nozzle exit : Moist air at 35 degree C, 3 bar, and relative humidity 30% (State 1) enters a nozzle with a velocity of 50 m/s and expands in a reversible and adiabatic process such that the moist air leaving the nozzle is about to condense (State 2). Calculate the ..

Reviews

Write a Review

Mechanical Engineering Questions & Answers

  A thin circular cylindrical shell subjected to internal

a thin circular cylindrical shell subjected to internal pressure p isnbspsimultaneously compressed by an axial load p

  If the turbine is 90 percent efficient how much energy can

a turbine is designed to extract energy from a water source flowing through a 10 cm diameter pipe at a pressure of 800

  The system is allowed to come to equilibrium determine the

an isolated system consists of a closed copper vessel of mass 0.1 kg containing 1 kg of liquid water each initially at

  If the volume of the air in the tank is 2 cubic meters find

an insulated rigid-wall tank contains air at 20 c and 2 bar. a paddle wheel located in the tank does work on the air in

  Determine the minimum molar flow rate of the cooling water

A total condenser is to be designed for condensing saturated 2-butanol vapor to form saturated 2-butanol liquid at 1 atm at the rate of 0.72 kmol/h. The saturation temperature of 2-butanol vapor at 1 atm is 99.6C. Cooling water at 25C and 1 atm is av..

  At what pressure in the test section must the tunnel

a 110 scale model of an automobile is tested in a pressurized wind tunnel. the test is to stimulate the automobile

  The mean residence time and volume of each reactor if the

three cstr are to be used in series. the second reactor has a volume twice that of the first and the third reactors.

  Consider some hypothetical x - y - ion pair for which the

consider some hypothetical x - y - ion pair for which the equilibrium interionic spacing and bonding energy values are

  The wafer is insulated at the bottom a calculate the

an annealing process shown uses a hot plate operating at an elevated temperature of 635 c. the wafer initially at a

  Water enters an insulated nozzle operating under steady

water enters an insulated nozzle operating under steady conditions at a pressure of 60 psia a temperature of 350 degf

  The bottom of the gate is 45 m below the water surface

a gate in the shape of a quarter cylinder hinged at a and sealed at b is 3 m wide. the bottom of the gate is 4.5 m

  The drain from the closed heater is trapped to the open

steam flow rate kgs for a reheat-regenerative steam power plant which is to produce 200 mw of electricity. the turbine

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd