Water is the working fluid in an ideal Rankine cycle. The steam enters the turbine at 15 MPa and enters the condenser at 10 kPa with a quality of 90 %. The mass flow rate of the water in the system is 120 kg/s.
Determine:
a) the temperature entering the turbineb) the rate of heat transferred to the steam in the boiler (kW)c) the net power developed (kW)d) the thermal efficiencye) the mass flow rate of condenser cooling water, if the cooling water undergoes a temperature increase of 18oC with negligible pressure change in passing through the condenser.
a what is the total volume of air drawn into the three cylinders each time the engine executes one revolution?b what is
steam contained in a piston amp cylinder appartus is initially at 200kpa and x0.8. this pressure is sufficient to hold
a vapor in a cylinder is compressed frictionlessly from 20 to 60 psia in such a manner that pvconstant. the initial
a load of 500 pounds is placed on a cylinder of 1040 carbon steel with a 2 inch radius. calculate the stress in
the thermometer in this problem a thermometer has a time constant of 10s and behaves as a first-order system. it is
an insulated piston-cylinder device contains 0.05m3 of saturated refrigerant-134a vapor at 0.8mpa pressure. the
air at 40 degree c and 1 atm at volumetric flow rate of 1.5 m3s is joined with co2 at 120 degree c and 1 atm in pipe
a piston-cylinder initially contains 2.52 kg saturated liquid water at 200 degrees celcius. now heat is transferred to
an alluminum ball 0.5 cm in diameter initially at 250 c is dropped into a large tank of fluid with tsat100 c which is
a rectangular channel 3-m-wide carries 10 m3s at a depth of 2m. is the flow subcritical or supercritical? for the same
Determine the acceleration of the cabinet when sA = 40 ft. Note that when sB = 0, sA = 0 (points A and B are coincident).
liquid water state 1 and steam state 2 are mixed in a steady flow open feedwater heater and the mixture leaves at state