A 2000 KVA, 4800-600V, 60 Hz, core type transformer operating at no load in the step down mode draws a magnetizing current equal to 2 percent rated current. The core has a mean length of 3.15 m, and is operating at a flux density of 1.55 T. The magnetic field intensity is 360A-t/m. Determine A) the magnitizing current; B) the number of turns in the two coils; C) the core flux; D) the cross-sectional area of the core.
A 340 V, 6 pole dc Shunt motor has the following parameters: Rating: 35 kW Current: 122 A Speed: 1000 rpmArmature resistance: 0.35 Ohm Sunt field resistance: 150 Ohm Friction&Windage loss: 1.2 kW
A) Determine the individual residues at the single poles at s = 0 and at s = -1 B)determine the two residues at the complex conjugate poles C) using the inverse laplace transform of the single poles and the complex conjugate poles determine the time..
An amplifier has a power gain of 3dB and an input signal power P(In) = 100mW. What is the output power level A tank circuit coil is operating at a resonance frequency f(res) = 20 MHZ; The circuit must operate with a bandwith of 200 KHZ.
For the system specified by the following difference equation, compute the first five samples of the response to the input given as x(n)=e^-0.4n u(n-1). The system is initially at rest. y(n)=y(n-1)-2y(n-2)+x(n)-0.8x(n-1)
Assuming a positive sequence operation, calculate the exact ABCD parameters of the line. Compare the exact B parameter with that of the nominal n circuit. Also compare the equivalent and nominal n circuits for the line.
Along the way to the page, they pass into a region between two deflecting plates that are 1.6 cm long. There is a 1,500,000 N/C electric field between the deflecting plates. You measure the distance from the edge of the plates to the paper and fin..
A 240/40 volt transformer supplies two different secondary loads. One load (a) draws a current of 12 amperes at a lagging power factor of 0.94. The other load (b) draws a current of 12 amperes at a leading power factor of 0.94.
specify the parameters Rin, Avo, and Ro of an amplifier that is to be connected between a 100k ohm source and a 2k ohm load and is required to meet the following specifications: A. No more than 10% of the signal strength is lost in the connection t..
What is the maximum number of receptacles permited on a 15A; 120V branch circuit. A 20 A 120 V circuit. How many small appliances branch circuits are required to supply receptacles in the kitchen and dining areas of residences
What are some of the possible biases and points of error that may arise in team communication systems and what are the advantages and disadvantages of a transactive memory system (TMS) in a team
If vid is 20-mV peak-to-peak sine wave applied in a balanced manner but superimposed on VCM = 0.5 V, what is the value that VDD must have to ensure saturation-mode operation for Q1 and Q2 at all times. Assume Vt = 0.5 V.
Two parallel connected 10 kV to 120 V 60 Hz single phase transformers supply a varying load. Assuming 0.85 PF, what is the maximum load current that can be supplied by this parallel combination of transformers wihout overloading either of them