A 50 ohms lossless transmission line is to be connected to a load of 25 ohm. Use a lamda/4(quarterLamda) length of line of unknown impedance between the load and the 50-ohm line to match it, which implies that there is no reflection. Determine the impedance of the quarter wave line?
In the differential amplifier shown in the schematic, R1 = R2 = 10 k ohm; R3 = R4 = 100 k ohm. Assume the ECG voltage at V1 = 100 mV, and the ECG voltage at V2 = - 100 mV. There is a power line interference of 200 mV at both input sites.
Suppose that a voice signal normally occupies 30 kHz of bandwidth and has a signal-to-noise ratio of 20 dB. Spread-spectrum techniques are used to increase its bandwidth to 2 MHz. (a) What is the signal-to-noise ratio of the spread signal
Characteristics of a filter, A filter has the following characteristics: Attenuation = 3.0 dB from 0 Hz to 2 kHz. From 2 kHz to 20 kHz attenuation increases from 3 dB to 23 dB in a straight line when plotted on axes of power in decibels (vertical a..
a parallel plate transmission line is made up of perfect conductors of width w = .2m and d = .01m. The medium between the plates is a diaelectric of epsilon = 2.25*(epsilon not) and mu = mu not. For a uniform plane wave propagating down the line
1) 70 lbs/hr of steam at 300 psia, 500oF passes through a turbine which expands it to a pressure of 30 psia. If the turbine operates with an efficiency of 70%: a) What is the temperature of the steam leaving the turbine
what do u mean by term slip of three phase induction motor calculate the slip of 4-pole induction motor running at 1470 rpm while bieng connected to a 50 hz three phase source
What are the positive and negative implications of wireless energy?
The internet connection speed at any time from your home can depend on the amount of overall internet trac at that time. Let the random variable X denote the speed of connection in megabits per second (MBPS).
1 To double the corner frequency in the low-pass and high pass two-pole filters, how would you change the values of the resistors and capacitors .2 Compare the one pole RC filters used in an active setup versus the passive setup
Control Systems- PID Controller, Which one of the following statements regarding the operation of a PID controller is definately false?
Three loads are connected in parrallel across a 250 Vrms line. Load 1 absorbs 16 kW and 18 kVAR. Load 2 absorbs 10 kVA with a power factor of 0.6 leading. Load 3 absorbs 8 kW with a power factor of 1.
A new phone company wants to provide very cheap voice-only cell phone capability to 200,000 simultaneous users in San Francisco. They transmit only 8kbs per duplex channel using FDMA (frequency division multiple access) and BPSK (1 bit/Hz).