Determine the coil load, circulation and ventilation airflow rates, and thermodynamic states for a CAV system at design conditions for a commercial office building. The design ambient conditions are 92 F dry bulb and 78 F wet bulb. The building can be treated as a single zone with a total zone load of 500,000 Btu/hr and a sensible heat ratio of 0.8. The design occupancy is 80 people and the corresponding ventilation air flow rate is 1600 cfm, which is based on 20 cfm of outdoor air per person. The zone temperature thermostat setting is 77 F, which is within the summer comfort zone. The bypass factor for the coil is 0.175 and the chilled water temperature is 50 F.
Specify the proper fail-safe action for the valves in the following services. Please explain your reasons. A valve manipulates the flow of natural gas (combustible) to a furnace. Another valve manipulates the flow of combustion air to the same fur..
an acher shoots an arrow vertically upward. if the arrow ascends to a maximum height of 100 feeta find the value of
air enters a compressor operating at steady state at 0.12 mpa 300k and a volumetric flow rate of 8 m3min. the air is
a child of mass 20 kg is standing on a plank inclined at 20 degrees to the horizontal. how much force does the child
suppose you are a materials engineer working for a beverage company and have been asked to identify what material
The drag coefficient (Cd) of a semi-tractor trailer without a cab fairing is 0.96,and with the fairing is 0.76 based on frontal area of 80ft^2. if power=Force * velocity, determine the horsepower (Hp) reduction of using the fairing in the truck is go..
hot air at 800c is blown over a 2-m x 4-m flat surface at 300c. if the average convection heat transfer coefficient is
a piston-cylinder contains 1.2 kg of saturated water vapor at an initial temperature of t1 200 oc.
The elevation of the surface of the lake is 928.75, and the invert of the orifice is 905.25. When the orifice is opened, what discharge in cfs flows through into the stream below the dam?
refrigerant 134a at -10degc 1.4 bar and a mass flow rate of 280 kghr enters an insulated compressor operating at steady
The gage pressure of the air in the tank shown in Fig P1-73 is measured to be 80 kPa. Determine the differential height h of the mercury column.