Balloons are often filled with helium gas because it weighs only about one-seventh of what air weighs under identical conditions. The buoyancy force, which can be expressed as (Fb=p-air g Vballon), will push the balloon upward. If the balloon has a diameter of 12 m and carries two people, 85 Kg each, determine the acceleration of the balloon when it is first released. Assume the density of air is p= 1.16 kg/m^3, and neglect the weight of the ropes and the cage.
A capacity coupled amplifier has a midband gain of 1000 V/V, a single high-frequency pole at 10 kHz, and a single low-frequency pole at 100 Hz. Negative feedback is employed so that the midband gain is reduced to 10.
A transmission line with no loss, with Z0= 60 ohms, is operated at 60MHz. The velocity on the line is c. The line is soldered to a ground connection at z=0. Find the input impedance into this line at z= -1.25 meters
Rated voltage is applied to the low voltage winding and the high voltage winding is open-circuited. Under this condition, the current into the low voltage winding is 2.4 A, and the power taken from the 2400 V source is 3456 W.
A load has a 20 ohm resistor and a 4 Henry inductor connected in series. It is connected to a power source with v(t) = 100 cos(50t), connected in series to the load. What is the impedance of the load? Use phasor transform methods to obtain your an..
What is the bandwidth required so that the modulated signal contains atheist 90% of the power of the unmodulated carrier. A carrier signal c(t) = 10 cos(2pifct) is modulated using a message signal m(t) cos(20pit). The modulation is FM, with kf = 50.
three single-phase transformers rated at 250kVa, 7200V/600, 50Hz, are connected in wye-delta on a 12470V, 3 phase line, if the load is 450kVA, calculate the current in the incoming and outgoing transmission lines and in the primary and secondary w..
The angle of departure is defined as 180 degrees plus the phase angle of GH computed at the complex pole, but ignoring the contribution of that particular pole.
Develop the Datapath; draw it under VISIO for this java code : input . x - the abscissa at which the linear interpolation is to be evaluated xi[]- the arrays of data abscissas yi[]- the arrays of data ordinates imax- size of the arrays xi[] and yi[]
if the equation for a mesh current is done and the current comes out negative, with the assumed clockwise direction. does that mean that the current is actually going in the opposite direction
A digital filter is to be designed using bilinear transform method. The expected frequency response specification of the filter is given in the following figure. fS = 8,000 Hz. I. Specify the filter frequency response versus normalized frequency
A three phase 4.157kv 60hz power system serves a 2880kva load pf=.8 lagging. Draw the ac equivalent circuit with load impedance element equated. The load is delta connected. solve for all the current (6 total).
A 500kVA ,7200-240V, 60Hz, transformer with 2.2% impedance was severly damaged as a result of a dead short across secondary terminals. Determine a) The short-circuit current;