Using the ACI coefficients, design a continuous reinforced concrete beam that will span four supports. The end spans are 24-ft long; the center span is 28-ft long (spans are measured center to center of supports). The exterior support (a spandrel beam) and the interior supporting girders have widths b of 18 in. The service loads are 0.90 kip/ft dead load (not including the weight of the beam) and 1.10 kip/ft live load. Use f′c = 3000 psi. Use only tension rein forcing. Design for moment only. Use the recommended bar cutoffs shown in Figure.
steam enters a 10000 hp turbine at 1600 lbfin2 and 1400 f and exits 10 lbfin2 and a quality of .9. the measured heat
an air-standard otto cycle operates with 520 degrees r and 14.7 psia at the beginning of the compression portion of the
Determine the maximum tensile and compressive stresses in portion BC of the beam and determine the final length, width, and thickness.
An ideal vapor-compression refrigeration cycle uses R-134a as the working fluid in an air-conditioning system. The refrigerant enters the compressor as a saturated vapor at 40 °F
IN FE analysis, What is effect of modeling a plane stress as plane strain and vice a versa?
augmented lagrangian method embedding technique amalgamated formulation what are the differences? what are the benefits
Describe the application and identify ALL of the key mechanical property requirements of the material in the application. What are the important failure mechanisms that MUST be considered in material selection for this application
a cantilevered bar is 500 mm long with square cross section 25mm x 25 mm. three perpendicular forces are applied to its
the object abc consists of two slender rods welded together at point b. tod ab has a mass of 1kg and a length of 0.3m
a large tower is to be supported by a series of steel wires.it is estimated that the load on each wire will be 11100N. determine the minimum required wire diameter assuming a factor of safety of 2 and a yield strength of 1030MPa.
the concrete beam is reinforced with three 20-mm diameter steel rods. assume that the concrete cannot support tensile
a feeder heater extracts steam from a turbine at 600kpa and 250c which it combines with 0.3 kgs of liquid at 600 kpa